Ideal power equation of the Transformer {The ideal transformer as a circuit element}

If the secondary coil is attached to a load that allows current to flow, electrical power is transmitted from the primary circuit to the secondary circuit. Ideally, the transformer is perfectly efficient. All the incoming energy is transformed from the primary circuit to the magnetic field and into the secondary circuit. If this condition is met, the input electric power must equal the output power:Ideal power equation of Transformer
giving the ideal transformer equation:Ideal power equation of Transformer
Transformers normally have high efficiency, so this formula is a reasonable approximation.
If the voltage is increased, then the current is decreased by the same factor. The impedance in one circuit is transformed by the square of the turns ratio. For example, if an impedance Zs is attached across the terminals of the secondary coil, it appears to the primary circuit to have an impedance of (Np/Ns)2Zs. This relationship is reciprocal, so that the impedance Zp of the primary circuit appears to the secondary to be (Ns/Np)2Zp.
 
You may Also Read:

 Image and some of Description are taken out from Wikipedia

EasyEDA: Ideas for Circuit Design, Innovation for Electronics Access
Free Circuit Design: Schematic - Simulation - PCB Layout - Gerber Viewer
Cheapest PCB Prototype: Only $2 for 10pcs, 24 hours Quick Turn, DHL Delivery in 3 days

About Electrical Technology

All about Electrical & Electronics Engineering & Technology. Follow , Facebook , Twitter , Instagram , Pinterest & Linkedin to get the latest updates or subscribe Here to get latest Engineering Articles in your mailbox. Also, Follow

Check Also

What is the normal or average life expectancy of a Transformer ?

When a Transformer is operated under ANSI / IEEE basic loading conditions (ANSI C57.96), its …

7 comments

  1. Very interesting post. Thank you!

  2. Nice Post..what is Overload capacity in <a title="Electrical power transformer" href="http://www.proconcontrols.com/electrical-power-transformers.php&quot; rel="nofollow">Electrical power transformer</a>..?

  3. In the eqn we use induced emf in primary coil, how is it equal to the supplied emf in primary coil?

  4. Is P inconing =rated power in a ideal transformer<br />

Leave a Reply

Your email address will not be published. Required fields are marked *