Three phase induction motors are used on a large scale in industries. We may divide the abnormal conditions and causes of three phase motor this way.
Click image to enlarge
Abnormal Operating Condition and Causes of Induction Motors
Abnormal Operating Condition and Causes of Induction Motors (Photos by Siemens)

following are the Abnormal Operating Condition and Causes of Induction Motors

Mechanical Overload
  • Block the pump or gear system connected with motors
  • Damaged bearings or No Lubrication
  • Lock rotor or more time to starting the motor
  • Stalling the motor (When motor does not start due to heavy load)
  • In this case, motor is disconnected from supply as well as from mechanical load. After that, motor is started to satisfy the mechanical overlord condition.
Abnormal Supply Conditions
  • Low Supply Voltage
  • Unbalance supply voltage
  • Increase in Supply Voltage
  • Low Frequency (than normal frequency)
Faults in Supply Circuit
  • Not availability of three phases
  • Short circuit in supply cable
  • Damaged links of the contactor
  • Melted Fuse
Internal Faults in Motor
  • Phase to Phase faults
  • Phase to Earth faults
  • Open Circuit
  • Bad Insulation of The motor windings (in this case, motor is checked with megger)

From Schematic Drawing to PCB Production, Just Need One Tool
Cheap PCB Prototype: 10 pcs 2 layers only $10, quick delivery, 100% E-test.

About Electrical Technology

All about Electrical & Electronics Engineering & Technology. Follow , Facebook , Twitter , Instagram , Pinterest & Linkedin to get the latest updates or subscribe Here to get latest Engineering Articles in your mailbox. Also, Follow

Check Also

DC Drives – Construction, Working & Classification of Electrical DC Drives

DC Drives – Construction, Working & Classification of Electrical DC Drives

What are DC Drives? Working & Operation of DC Drives DC drive technology is efficient, …

4 comments

  1. *Order* an H-bridge? I made one myself last night from raw tronsistars. Well I think I did. I made an H-bridge simulator anyway. It only lights LEDs so far. Also, I’ll probably blow out the tronsistars since I don’t know how to read the datasheet well enough to see what max current they’ll take.

  2. omprakash pawar

    Why induction motor is not run on synchronous. Speed?

  3. dileep shukla

    kindly explain how much check insulation resistance and phase to phase resistance?
    kindly tell us formula to check resistance by varios motors.

  4. Sathish Kumar.A

    usefull information about us