Cramer’s Rule | Cramer’s Rule Calculator 2 & 3 Equations System

Cramer's rule. step by step procedure with solved example

Cramer’s Rule & Calculator for Linear Circuit Analysis | Step by Step with Solved Examples Today, we are going to share another simple but powerful circuit analysis technique which is known as “Cramer’s Rule“. SUPERMESH Circuit Analysis | Step by Step with Solved Example Update: We have added Online Cramer’s Rule Calculator where you can solve two equations system as …

Read More »

Advance Voltage Drop Calculator and Voltage Drop Formula

Advance Voltage Drop Calculator and Voltage Drop Formula

Advance Voltage Drop Calculator and Voltage Drop Formula. According to the NEC (National Electric Code) [210.19 A (1)] FPN number 4 and [215.2 A (3)] FPN number 2, the allowable Voltage drop for feeders is 3% and the acceptable voltage drop for final sub circuit and branch circuit is 5% for proper and efficient operation. For example, if the Supply …

Read More »

Wire & Cable Size Calculator in AWG

Cable Size Calculator in AWG As we have already discussed that how to select the proper wire size for Electrical wiring installationin  detail under the topic of How to determine the suitable size ofcable for Electrical Wiring Installation with Solved Examples (in both British and Si System). Now we are here to present the Wire and cable size calculator for you. …

Read More »

IC 555 Timer Calculator with formulas & Equations

IC-555-Timer-Calculator-with-formulas-amp-Equations

IC 555 Timer Calculator with formulas & Equations IC 555 Timer Calculator with formulas & Equations IC 555 Timer Calculator with formulas & Equations IC 555 Timer Calculator with formulas & Equations Formulas and Equations for This calculator Frequency (f) = 1/ [ ln(2) x C x (R1 + 2R2) ] Frequency (f) = 1.44 / C x (R1 + …

Read More »

Battery Capacity Calculator

Battery Capacity Rating Calculator Formula and Equations for Battery Capacity Calculator Battery Capacity in mAh= (Battery life in hours x Load Current in Amp) /0.7 Battery Capacity= (Hours x Amp) / Run Time % Where; Battery Capacity = in mAH (milli Ampere hours) Battery life = in Hours Load Current = Consumption of device in Amperes 0.7 = Battery Cycle …

Read More »

Battery Life Calculator

Battery Life Calculator   Formula and Equations for Battery Life Calculator Battery life = (Battery Capacity/ Load Current) × 0.7 Battery Life = (Ah rating of Battery / Amp) x Run Time % Where; Battery life = in Hours Battery Capacity = in mAH (milli Ampere hours) Load Current = Consumption of device in Amperes 0.7 = Battery Cycle life considerations (Run …

Read More »

Zener Diode & Zener Voltage Regulator Calculator

Zener Diode & Zener Voltage Regulator Calculator Formulas and Equations for Zener Diode & Zener Voltage Regulator Calculator Series Current IS= VIN – VZ / RS….. (Ohm’s Law Again) Load Voltage VL = VZ Change in Load Voltage ∆VL = IZ x RZ Output (Regulated) Voltage VOUT= VIN – IR = VIN – (IZ + IL) / RS = (VIN …

Read More »

Power, Voltage, Current & Resistance (P,V,I,R) Calculator

Power, Voltage, Current & Resistance (P,V,I,R) Calculator Formula & Equations for Power, Voltage, Current & Resistance (P,V,I,R) Calculator This calculator is based on simple Ohm’s Law. As we have already shared Ohm’s Law (P,I,V,R) Calculator In which you can also calculate three phase current. But we have designed this one especially for DC Circuits (as well as work for Single …

Read More »