Clap Switch Circuit Electronic Project Using 555 Timer

Clap Switch Circuit Electronic Project Using 555 Timer

Clap Switch Circuit Electronic Project Using 555 Timer & BC-547 Transistors Introduction Clap Switch is a basic Electronics mini-project, made with the help of the basic components. Clap Switch has the ability to turn ON/OFF any electrical component or circuit by the clap sound. It is known as Clap Switch, because the condenser mic which will be used in this …

Read More »

LED Resistor Calculator | Required Value of Resistor for LED’s Circuit Calculator

LED-simple-circuit-ever.how-to-calculate-the-value-of-resistor-for-LED

LED Resistor Calculator | Required Value of Resistor for LED’s Circuit Calculator LED Resistor Calculator This LED Resistor calculator will help you to find the proper value of resistor for LED’s circuit to connect with battery. Formula for this calculator Resistor Value = (Vs – VF)/ IF Where Vs = Input Supply DC voltage VF = LED Forward Voltage IF …

Read More »

Fun With LED’s Library

 Fun With LED’s Library How to calculate the value of resistor for LED’s (with different types of LED’s circuits) Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple. LED String/Strip Circuit Diagram Using PCR-406 Generator From Motor. Very Simple. Required Value of Resistor for LED’s Circuit Calculator Emergency LED Light. Powerful & Cheap Circuit LED-716 Emergency …

Read More »

How to Calculate the Value of Resistor for LED’s (with different types of LED Circuits)

LED-Symbol-LED-Construction-and-LED-Lead-identification

How to Calculate the Value of Resistor for different types of LED’s Circuits This tutorial will help you to find the proper value of resistor (or resistors) for one or more LED’s to connect with battery. If you pick this topic, you will be able to: Calculate the value of resistors for different LED’s Circuit diagrams Calculate the Forward Current …

Read More »

Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple.

 Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple.Briefing: Her is our new simple Electrical/Electronics project about Automatic Street Light Control System.  it is a simple and powerful concept, which uses transistor (BC 547 NPN) as a switch to switch ON and OFF the street light system automatically. It automatically switches ON lights when the sunlight …

Read More »

Generator From Motor. Very Simple.

 Generator From Motor. Very Simple.Here we used two 12 Volts toy/ Old Tap-recorder Motors(From trash). One as a Motor ( Turbne) and other one as a Generator/alternator. A whitle LED is coneccted as a Load to the Generator Ourput.Note That this is seems to be a Motor-Generator Set, but No.. Because Motor-Generator Set ( AC Motor and DC Generator) used …

Read More »

Make a Simple Generator to Understand the working Principle of Generator/Alternator. (Spool Generator)

 Spool Generator. Requirements: Insulated copper wire around 26 SWG 400 turns (you may also use 35 SWG) Neodymium strong magnets Plumbing tape spool 2 Safety pins or paper clip (same size) Straw pieces LED Rubber piece Straw pieces Procedure: Turn 400 turns of 26 gage insulated copper wire around the empty spool of plumbing tape. (You may also use 800 …

Read More »