Is Reactive Power Useful? Importance of Reactive Power

Is Reactive Power Useful? Importance of Reactive Power

What is Reactive Power and Why it is Useful?  In recent years, the reactive power control has been the subject of a systematic study as it plays an important role in maintaining a secure voltage profile in a large scale transmission system. Though it is a byproduct of alternating current systems, it is needed for the acceptable functioning of various …

Read More »

SCADA Systems for Electrical Distribution

SCADA Systems for Electrical Distribution

SCADA Systems for Electrical Distribution Nowadays, computer control is one of the most cost effective solutions for improving reliability, optimum operation, intelligent control and protection of a power system network. Having advanced data collection capabilities, SCADA system plays a significant role in power system operation. Typically, at distribution side SCADA does more than simply collecting data by automating entire distribution …

Read More »

What Exactly Is A Smart Grid? Smart Grid Applications

What does a Smart Grid do?

Smart Grid & Their Application in the Grid System What is Grid? Concept of smart grid is quite in the news and market but majority of the people actually don’t know that what exactly are the things which make a grid smart? The term “Grid” refer to an “Electric Grid” basically describes a complete network which includes transmission lines, transformers, …

Read More »

Integration of Renewable Energy with Grid System

Integration of Renewable Energy with Grid System

Integration of Renewable Energy with Grid System Types of energy which exist infinitely and never run out completely are renewable forms of energy. Consider wind, coal, biomass, propane , uranium, water ,sun, these are the sources that are naturally available to us, never run out and they were not formed. Far in history concept of production of electricity from these …

Read More »

Why Power Transmission Cables & Lines are Loose on Electric Poles & Transmission Towers?

Why Power Transmission Cables & Lines are Loose on Electric Poles & Transmission Towers?

INTRODUCTION Transportation of people, goods and services today is no longer a problem as technology is fast growing. Distance is neither a barrier nor a problem. Just as people, goods and services are easily transported across a distant destination, ELECTRICITY is no different. Electricity can be transported over a long distance. But unlike goods, electricity requires a medium through which …

Read More »

Why Power Plant Capacity Rated in MW and not in MVA?

For the following reasons, a Power plant capacity rating may be expressed in MW instead of MVA. In a Generating station, the prime mover (Turbine) generates only and only Active Power. That’s why we rated a power plant capacity in MW instead of MVA. Its mean no matter how large your generator is, but it depends on the capacity of …

Read More »

How to Convert Capacitor Farads into kVAR & Vice Versa (For Power factor improvement)

How to Convert Capacitor Farads into kVAR & Vice Versa For Power factor

How to Convert Capacitor Farads into kVAR & Vice Versa for Power factor improvement? How to Calculate the Required Capacitor bank value in both kVAR and Farads? (How to Convert Farads into kVAR and Vice Versa) How to Convert Capacitor Farads into kVAR & Vice Versa (For Power factor improvement) In this simple Calculation tutorial, we will find the way …

Read More »

Advantages of Power factor improvement and Correction

 Advantages of Power factor improvement and Correction: Following are the merits and benefits of improvedPower factor; Increase in efficiency of system and devices Low Voltage Drop Reduction in size of a conductor and cable which reduces cost of the Cooper An Increase in available power Line Losses (Copper Losses) I2R is reduced Appropriate Size of Electrical Machines (Transformer, Generators etc) …

Read More »