What is Stepper Motor: Construction, Types and Modes of Operation

What is Stepper Motor: Construction, Types and Modes of Operation

All You Have to Know about Stepper Motor: Types and Modes of Operation The invention of dedicated stepper motor driver cards and other digital control technologies for interfacing a stepper motor to PC-based systems are the reason for the widespread acceptance of stepper motors in recent times. Stepper motors become the ideal choice for automation systems that require precise speed …

Read More »

What is Voltage Stabilizer & How it Works?

What is Voltage Stabilizer. Difference between Stabilizer & Regulator

What is Voltage Stabilizer and Why we need it? Stabilizer Operation, Types and Applications Introduction to Stabilizer: The embedding of microprocessor chip technology and power electronic devices in the design of intelligent AC voltage stabilizers (or automatic voltage regulators (AVR)) led to produce high-quality, stable electric power supply in the event of significant and continuous deviation of mains voltage. As …

Read More »

All about MCB, its Construction, Working, Types & Applications.

What is MCB (Miniature Circuit Breaker), its Construction, Working, Types & Applications

What is MCB (Miniature Circuit Breaker), its Construction, Working, Types & How to select proper MCB for different loads rating? Introduction to Miniature Circuit Breakers (MCBs) All fuses need to be replaced when they have operated. Unlike a fuse, an MCB operates as automatic switch that opens in the event of excessive current flowing through the circuit and once the …

Read More »

How to Find the Size of Earth Conductor, Earthing Lead & Earth Electrodes?

How to Find the Size of Earth Conductor, Earthing Lead & Earth Electrode

Calculate the size of Earth Continuity Conductor, Earthing Lead & Earth Electrodes? For earhing or grounding purposes, the size of earth continuity conductor,, earthing lead and earth electrodes depend on wiring cables used in the system. Solved example given below will make the point easy to understand that how to determine the proper size of earth conductor, earth lead and …

Read More »

Power Distribution in Industries – All You Need to Know

Everything You Need to Know about Power Distribution in Industries

Power Distribution in Industries – Everything You Need to Know Today we are intended to take you to the industrial environment by giving the picture of how an electric power distributed in industries. In industries, electrical panels play a major role in distributing the power that houses various equipments such as bus bars, circuit breakers, meters, etc. These panels are …

Read More »

Difference Between MCB & MCCB According To IEC Standards

MCB or MCCB - Difference in IEC Standards - IEC 60898-1 & IEC 60947-2

MCB or MCCB – Difference in IEC Standards (IEC 60898-1 & IEC 60947-2) Circuit breakers are installed and used for safety purposes in both residential as well as commercial and industrial areas. In power distribution, we need circuit breakers at different levels. Depending on the current carrying capacity, breaking capacity and other functions, we select a suitable circuit breaker according …

Read More »

What is PID Controller & How it Works?

PID Controllers What they are and how they work

How PID Controllers Works? PID Controller is a most common control algorithm used in industrial automation & applications and more than 95% of the industrial controllers are of PID type. PID controllers are used for more precise and accurate control of various parameters. Most often these are used for the regulation of temperature, pressure, speed, flow and other process variables. …

Read More »

What is LabVIEW and How to make basic Electrical Projects in LabVIEW?

What is LabVIEW and How to make basic Electrical Projects in LabVIEW?

Introduction to LabVIEW and Basic LabVIEW Based Electrical Projects As a proven useful tool for prototyping, the LabVIEW graphical development platform delivers a numerous solutions to a wide variety of applications such as instrumentation control, embedded monitoring and control systems, data acquiring and processing, automation test and validation systems, etc. LabVIEW includes hundreds prewritten libraries which help to create flexible …

Read More »

Different Types of Wiring Systems and Methods of Electrical Wiring

Electrical Wiring Systems. Cleat Wiring

Methods of Wiring And Different Types of Wiring Systems¬† Methods of Electrical Wiring Systems w.r.t Taking Connection Wiring (a process of connecting various accessories for distribution of electrical energy from supplier’s meter board to home appliances such as lamps, fans and other domestic appliances is known as Electrical Wiring) can be done using two methods which are Joint box system …

Read More »