What is Distributed Control System (DCS)?

What is Distributed Control System DSC

What is Distributed Control System DCS? In recent years, the use of smart devices and field buses makes distributed control system (DCS) to be prominent in large and complex industrial processes as compared to the former centralized control system. This distribution of control system architecture around the plant has led to produce more efficient ways to improve reliability of control, …

Read More »

Internet of Things (IOT) and Its Applications in Electrical Power Industry

Internet of Things in Electrical Engineering & Power System Industries

What is Internet of Things (IOT) and Its Application in Electrical Power Systems Several recent digital and smart manufacturing technologies, and design innovations besides the internet connectivity origins Internet of Things (IOT) to become a revolutionary technology in transforming many areas of modern day living. Though the inception of IOT was started in the context of supply chain management, it …

Read More »

Is Reactive Power Useful? Importance of Reactive Power

Is Reactive Power Useful? Importance of Reactive Power

What is Reactive Power and Why it is Useful?  In recent years, the reactive power control has been the subject of a systematic study as it plays an important role in maintaining a secure voltage profile in a large scale transmission system. Though it is a byproduct of alternating current systems, it is needed for the acceptable functioning of various …

Read More »

Power Distribution in Industries – All You Need to Know

Everything You Need to Know about Power Distribution in Industries

Power Distribution in Industries – Everything You Need to Know Today we are intended to take you to the industrial environment by giving the picture of how an electric power distributed in industries. In industries, electrical panels play a major role in distributing the power that houses various equipments such as bus bars, circuit breakers, meters, etc. These panels are …

Read More »

SCADA Systems for Electrical Distribution

SCADA Systems for Electrical Distribution

SCADA Systems for Electrical Distribution Nowadays, computer control is one of the most cost effective solutions for improving reliability, optimum operation, intelligent control and protection of a power system network. Having advanced data collection capabilities, SCADA system plays a significant role in power system operation. Typically, at distribution side SCADA does more than simply collecting data by automating entire distribution …

Read More »

What Exactly Is A Smart Grid? Smart Grid Applications

What does a Smart Grid do?

Smart Grid & Their Application in the Grid System What is Grid? Concept of smart grid is quite in the news and market but majority of the people actually don’t know that what exactly are the things which make a grid smart? The term “Grid” refer to an “Electric Grid” basically describes a complete network which includes transmission lines, transformers, …

Read More »

Integration of Renewable Energy with Grid System

Integration of Renewable Energy with Grid System

Integration of Renewable Energy with Grid System Types of energy which exist infinitely and never run out completely are renewable forms of energy. Consider wind, coal, biomass, propane , uranium, water ,sun, these are the sources that are naturally available to us, never run out and they were not formed. Far in history concept of production of electricity from these …

Read More »

High Inrush Current in Capacitor Switching and Ways to Prevent It.

Step to removing High Inrush Current in Capacitor Switching

How to Prevent the high Inrush Current in Capacitor Switching? Introduction to High Inrush Current in Capacitor Switching Applications of capacitance switching are not only restricted to capacitive currents but they have their implementation in energizing process of capacitors banks, overhead lines and cables. Capacitors banks switching are known to be cause of very large value of transient voltage across …

Read More »

Nuclear Power. Why is It The Last Option in Most Countries?

HOW ELECTRICITY IS GENERATED FROM NUCLEAR ENERGY. Nuclear Power

Nuclear Power: Why Other Countries Think Of It As The Last Option   INTRODUCTION Nuclear energy is becoming well developed as a source of energy. Compared to other sources of energy like solar energy, and hydroelectricity, nuclear energy is more stable in that its power supply is stable. Power generated by hydroelectric power plant is always dependent on the volume …

Read More »

Fault Current Limiter and Their Types

Superconductor Current limiting Reactors. Fault current Limiter

Fault Current Limiter (FCL) & Current Limiting Reactors (CLR) Introduction to Fault Current Limiter: These days due to increase in demand of energy, solid development in generation and transmission is attaining importance and transforming into basic need, but in any generation system one of the main factor that is creating a lot of issues is short circuit and along with …

Read More »