How To Locate Faults In Cables? Cable Faults, Types & Causes

How To Locate Faults In Cables? Cable Faults, Types & Causes

Cable Faults, Types, Causes and How to locate faults in Cables via different Tests. Introduction to Faults in Cables When electrical energy is generated in the generations’ stations, it is distributed to the different loads, i.e. cities, towns and villages for consumption then. The process involves stepping up the voltage to minimize the loss of energy in the form of …

Read More »

How to Test & Fix the Printed Circuit Board (PCB) Defects?

Diagnosing of Defective Printed Circuit Boards PCB

Diagnosing of Defective Printed Circuit Boards (PCB) Before getting into details of printed circuit board (PCB), there are some basics you need to know about circuits. Electricity: It is the power provided to every instrument ranging from small lights to heavy machinery. Electricity is just a flow of electron from one level to other (upper level to lower mostly).So in …

Read More »

GFCI: Ground Fault Circuit Interrupter. Types & Working

How GFCI works? Ground Fault Circuit Interrupter

Ground Fault Circuit Interrupter (GFCI) At home or outside, there is no way can we do without electricity and electrical devices. These are the indispensible necessities of our modern day lives. But sometimes their accidental “touch” can give a painful shock resulting in serious injuries which at times, sadly enough can have fatal consequences. Do you know? Thousands of children …

Read More »

How to test a battery with Test meter?

How to test a battery with Test meter?

How to test a battery with Test meter? There are lots of tools and meters to test battery, car battery and cells to check and measure the battery efficiency and condition. Although, we can test battery with digital millimeter, but for an almost accurate checkup, we may use special tools like Digital Battery Tester, Multi-Battery Tester, 12 Volt Electronic Battery …

Read More »

Testing Electrical and Electronics Components and Devices with Multimeter

How To Test Electrical and Electronics Components with Multimeter

How To Test Electrical & Electronics Components with Multimeter? We all know the rule and importance of “Troubleshooting” in Electrical and Electronics Engineering. Most EE Components and Elements used in Electrical and Electronics Equipments, and Devices are common in their functions and operations. To be a good analyzer and troubleshooter, you must know the following basic techniques in Electrical and …

Read More »

Basic Electrical Engineering Tools and Their Uses

Electrical engineers are required to work in hazardous environments near energized equipment. There are certain tools they require to carry out their job effectively and safely without causing any harm to themselves and those around them. Here’s a sneak peek into some electrical engineering tools and their uses: Electronic Measuring Probes Current probes Current probes are one of the key …

Read More »

Repairing Library

 Repairing Library How to find The value of Burnt Resistor ( By three handy Methods ) General Capacitor Nameplate Rating (Electrolytic Capacitor) How to Check a Capacitor with Digital (Multi meter) and Analog (AVO Meter). By Four (4) Methods with pictorial View. How to Calculate/Find the value of Ceramic / Non-Polarized Capacitors? Basic Electrical Engineering Tools and Their Uses  Testing …

Read More »

How to find The value of Burnt Resistor ( By three handy Methods )

 How to find The value of Burnt Resistor ( By three handy Methods ) We can find the Values of burnt resistors by these three handy methods.                                                              Click Image to Enlarge Method 1 Scarp the outer coating. Clean the Burnt Section of the resistor Measure resistance from one end of the resistor to the damaged section Again measure the resistance from …

Read More »

General Capacitor Nameplate Rating (Electrolytic Capacitor)

General Capacitor Nameplate Rating (Electrolytic Capacitor) Following are the General requirements  for an Electrolytic Capacitor Nameplates. Manufacture’s NameCapacitor SeriesMaximum temperatureMaximum VoltagePolarityCapacitor’s Value(Capacitance in Farads,  µF, pF, or nF) Here is the typical nameplate rating on the electrolytic Capacitor (External Container Box) as shown in below image. Manufacture’s Name :       RubyconCapacitor Series:              CE                Maximum …

Read More »

How to Test a Capacitor? 4 Ways to Check a Capacitor

How to Test a Capacitor with Digital Multimeter and Analog AVO Meter. By Four (4) Methods with pictorial View.

How to Test & Check a Capacitor with Digital Multimeter and Analog AVO Meter. By Four (4) Methods with pictorial Views. In Most Electrical and Electronics troubleshooting and repairing, we face this trouble that how to test and check a capacitor? Is it Good, Bad (dead) Short or Open? Here, we can check a capacitor with Analog (AVO Meter i.e. …

Read More »