How to Wire Solar Panel to 220V inverter, 12V battery ,12V,DC Load?

How to Wire Solar Panel to 220V inverter, 12V battery ,12V,DC Load and 220V AC Load?

(220V fan, light etc / AC & DC Load) with automatic UPS System?

Show More

Electrical Technology

All about Electrical & Electronics Engineering & Technology. Follow , Twitter , Instagram, Pinterest, YouTube, & Linkedin to get the latest updates or subscribe Here to get latest Engineering Articles in your mailbox.

12 Comments

    1. Anonymous says:

      what are the types of solar panels available?

  1. Anonymous says:

    for this wiring, if we take the input of inverter not directly from the battery but from the 12 Vdc output of controller… what will happen? what are the pros and cons? thx..

    1. Electrical Technology says:

      by this way, you will not be able to store charges in the battery..in other words…you can use Solar panel out put during at day when sunlight available. battery is for emergency purpose or using electrical energy during night (when Sun light not available).

  2. oswin paul says:

    how many batteries do i need to connect to my 230 watts solar panel,and what sort of gadgets can i connect to my system,IE TV,computer,decoder,5 bulbs.

  3. Anonymous says:

    Sir waseem how many volt and watt in solar panel charging for 12v battery

  4. Anonymous says:

    i have 2000w inverter ,800watts solar panel and also 20A charger controller ,though i bought the charger controller before i got your site , i can change the controller to bigger one if recommended. But,i did not get the wiring of how to connect solar panel directly to sunlight in the day time. I have also search everywhere on your site to check proper connections but i cant find it.The one on

  5. Anonymous says:

    can I hook up my solar panel directly to a ups without a battery because I only want to use it during the day time and no back-up for night

  6. is it possible to transform the out put of the inverter using a transformer( stepping it up)

    1. Bong Ramos says:

      Techincally, yes. But instead of doing that, buy an inverter with desired output.

Leave a Reply