Home » Generation Transmission and Distribution

Generation Transmission and Distribution

Electric Stress Control in Cable, Joints & Terminations

Electric Stress Control in Cable, Joints & Terminations

How to Control Electric Stress in Cable Joints & Terminations? Introduction Power cables are of great importance in power transmission and distribution systems. Terminations and joints are the basic accessories of the power cables and they are required to make connections between lines or to an electrical apparatus. The various aspects are considered while designing the cable terminations and joints …

Read More »

Busbars and Connectors in HV and EHV installations

Tubular busbar

Busbars and Connectors in Indoor & Outdoor Installations What is Electric Busbar? A conductor or group of conductor used to collect the power from incoming feeders and distribute to the outgoing feeders is known as busbar. In other words, Busbar is a junction where the incoming  and outgoing feeders current meets i.e. it collects the power at single point. Busbars …

Read More »

Cables Feeder Protection – Faults Types, Causes & Differential Protection

Cables Feeder Protection – Types of Faults, Causes, Overcurrent & Differential Protection

Cables Feeder Protection – Overcurrent & Differential Protection Common Types of Faults Common failure modes and faults of cables are: Electrically induced failures Mechanically induced failures Thermally induced failures Metallic (semiconducting) shield damage Poor Metallic Shield Contact Explanation of each fault is follow respectively. Electrically induced failures These involve lightning, switching surges, and partial discharges. Partial discharges may be caused …

Read More »

Overhead Lines Protection – Faults & Protection Devices

Overhead Lines Protection - Faults & Protection Devices

Overhead Lines Faults & Protection in Power System Common Faults in Overhead Lines The most common causes of faults in overhead lines are: Aircraft and cars hitting lines and structures Birds and animals Contaminated insulators Ice and snow loading Lightning Partial discharges (corona) not controlled Punctured or broken insulators Trees Wind Related Article: Power Transformer Protection & Faults Overhead Lines …

Read More »

HV And MV Switch Disconnectors And Isolators in Power System

HV And MV Switch Disconnectors And Isolators in Power System

HV/MV Switch Disconnectors And Isolators in Substation & Overhead Lines Introduction HV/MV Switch Disconnectors And Isolators High Voltage (HV) and Medium Voltage (MV)[1] installations require equipments to switching and/or isolating circuits or parts of circuits. For that purpose switch-disconnectors and isolators are used. These equipments must comply with the following IEC[2] Standards: 60038 – IEC standard voltages 61936-1 – Power …

Read More »

Design and Installation of EHV/EHV and EHV/HV Substations

Design and Installation of EHVHV and EHVHV Substations - Types and Configurations

Types and Configurations of EHV/EHV and EHV/HV Substations The Role of EHV/EHV and EHV/HV Substations in Transmission Network EHV/EHV and EHV/HV[1] substations are an important element of the electricity transmission network of a country or of a large area of a country and their functions are: Interconnection of power plants of the national or area electrical grid. Step up and …

Read More »

All About Electrical Protection Systems, Devices And Units

Electrical Protection Systems And Units

Electrical Protection Units And Systems Introduction to Electrical Protection Systems HV, MV and LV[1] electric installations and equipments are subjected to internal and external faults that can cause serious damages in persons and other equipments. To avoid and to minimize the consequences of those faults protection devices associated to equipments that are able to break electric current are required. For …

Read More »

Maintenance of Transformer – Power Transformers Maintenance, Diagnostic & Monitoring

Maintenance of Power Transformer - Transformer Diagnostic and Monitoring

Maintenance of Power Transformer – Transformer Diagnostic and Monitoring Introduction Being transformers static machines without any moving and turning parts, they are very reliable machines, and if maintained properly, can last for 40 years or more. Also they do not trip or blow when oven-stressed (except under extreme conditions), transformers are frequently overloaded and allowed to operate well beyond its …

Read More »

Current Transformers (CT) – Types, Characteristic & Applications

Current Transformers (CT) - Construction, Types, Installation, Characteristic & Applications

Current Transformers (CT) – Construction, Types, Installation, Characteristic & Applications What is Current Transformer (CT) ? Current transformers (CT) are used in High Voltage (HV) and Medium Voltage (MV)[1] installations to give an image of electrical current to protection relays and units and metering equipment and they are designed to provide a current in its secondary proportional to the current …

Read More »