Domestic AC Voltage at Home is 230V but its Equation is v = Vm Sin θ. Explain the Difference?
Our homes are supplied with sinusoidal voltage whose equation should be (v = Vm Sin θ). But we always say that AC voltage at home is 230V. How do you explain this difference?
The domestic single phase AC supply is 230V, 50Hz (in EU) or 110V 60Hz in US. It is the RMS or effective value. It means that alternating voltage available has the same heating effect as 230V DC. The equation of this alternating voltage:
v = Vm Sin θ
v = Vm Sin ωt ….. (θ = ωt)
v = 230VRMS x √2 Sin 2π x 50 t ….. [Putting Vm = √2 VRMS and ω = 2π]
v = 230VRMS x √2 Sin 314 t Volts
In short, the figure of 110V or 230V is not the exact value of sinusoidal voltage at our homes supplied by the power house. But it is the exact value of RMS voltage i.e. we get the amount of AC voltage having the same effect of 110V DC or 230VDC respectively.
Keep in mind that the 230V AC in domestic supply has the peak value of 325VP (Peak Voltage) or 650VP-P (Peak to Peak Voltage) and 207VAVG (Average Voltage).
Same is the case for 110V AC which peak voltage, peak to peak voltage and average voltage are 155VP, 310VP-P, 99VAVG respectively by using the RMS value calculator and peak voltage calculator.
Related Posts:
- Difference Between Voltage and EMF?
- A Voltmeter, Ammeter & Cell are Connected in Series. Ammeter shows No Deflection. Why?
- Why an Inductor acts as a Short Circuit in DC Supply?
- Why the Reactance & Voltage under Fault Condition is Low and Current is High
- According to Ohm’s Law, I ∝ V, But I ∝ 1/V in Power Equation. Explain?
- Difference Between Real Ground and Virtual Ground
- Why Power Factor Decreases When Capacitive Reactance Increases or Capacitance Decreases?

Why are Inductive & Capacitive Reactances Measured in Ohms?
What Happens If You Install a Larger Capacitor in a Fan?
Difference Between Grounding, Grounded and Ungrounded Conductors
Difference Between AFCI, CAFCI, DFCI and GFCI?
Why is a Capacitor Bank Rated in kVAR, Not in Farad?
Why is the Rating of a Capacitor Expressed in Farad?