How to Test a Diode using Digital & Analog Multimeter – 4 Ways.

Test a Diode by Analog & Digital Multimeter

Troubleshooting Electronic Devices & Components

Troubleshooting in electronic and electrical engineering is an important part and one must know the basic skills and knowledge about the components to design and troubleshoot a circuit. It is advisable to test component before assembling and placing in a circuit.

Sometimes, we get unexpected results and we must perform some tests to find whether the component and device is working properly or we should replaced with a new one. For this purpose, we have started some Digital and Analog multimeters tutorials where we will discus how to test different electrical and electronics components. Today, we will have to discuss how to test a diode using DMM and AMM by 4 methods.

How to Test a Diode

Diode is a simple PN Junction and two terminal device which allow to flow current though it in one direction (Forward Bias). It is the most used component in different electronic designs and systems like rectifiers, LED lights related circuits, voltage multiplying circuits, solar panels, logic gates etc.

Diode Terminal Identification (Anode + Cathode)
Diode Terminal Identification (Anode + Cathode)

When the cathode terminal of diode is connected to the neutral and anode to positive, It is called in forward bias position and it acts like a short switch where current starts to flow through it. Cathode to positive and anode to neutral is called reverse bias and diode is acts as open switch which is know as reverse bias (This case is reverse in case of zener diode).

Before testing a diode, We must know the diode terminals like Anode (+) and Cathode (-). In most cases, there is a white band color coating on normal PN junctions diodes which indicates as cathode terminal and the rest is anode. In other cases, there are different colors are used and the color coated sides are cathode as shown in fig below. Below is a tutorial that shows how to test a normal PN Diode, LED, and Zener Diode by different methods..

Diode can be check and tested by 4 methods using digital or analog multimeters.

How to Test a Diode using Digital Multimeter

Testing Diode using DMM (Diode Test Mode + Resistance Mode)

How to Test a diode - Testing Diode using DMM (Diode Test Mode + Resistance Mode)
Testing Diode using DMM (Diode Test Mode + Resistance Mode)

The best practice to test a diode in “Diode test” mode by measuring the voltage drop across the diode in case of forward biased. Keep in mind that diode in forward-biased acts as closed switch which let to flow current in it like conductors. In reverse-biased diode, it acts like an open switch and doesn’t permit current to flow in it as it acts like a resistor.

Forward Biased: When the Positive (Red) test lead is connected to the anode (+) and negative (Black) test lead is connected to the cathode (-) of diode. In Forward-biased, the diode acts like close switch and will pass the current through it like conductors.

Reverse Biased: If we do the reverse as mention above i.e. RED Test lead to cathode (-) and BLACK test lead to the Anode (+) of the diode. In revere-biased, the diode acts like open switch and will not let pass the current through it like resistor.

Steps:

  1. Remove the diode from the circuit i.e. disconnect the power supply across the diode which has to be tested. Discharge all the capacitor (by shorting the capacitor leads) in the circuit (If any).
  2. Set the meter on “Diode Test” Mode by turning the rotary switch of multimeter.
  3. Connect the diode leads to the multimeter test leads and note the reading.
  4. Now, Connect the diode lead to the multimeter test leads in reverse direction (i.e. Reverse the test leads) and note the measurement.

Related Tutorial: How to find The value of Burnt Resistor ( By three handy Methods )

How to Test a Diode using Analog Multimeter

Testing Diode by Multimeter (DMM & AMM in Resistance Mode)

If “diode test is not available in case of digital multimeter or you have to test the diode with analog multimeter, Resistance mode (Ω) can be used to test the diode as alternative.

Click image to enlarge

Testing Diode by Multimeter (DMM & AMM in Resistance Mode)
Testing Diode by Multimeter (DMM & AMM in Resistance Mode)

Steps:

  1. Remove the diode from the circuit and make sure that power supply is disconnected from the circuit and there is no voltage across the diode which has to be tested. Also, discharge all the capacitors by shorting their leads in the circuits if any.
  2. Set the meter on “Resistance mode (Ω)” Mode by turning the rotary switch of multimeter. For better result, set the Ω range on 1kΩ for forward bias and 100kΩ for reverse bias as shown in fig below.
  3. Connect the RED test lead to the anode of the diode and BLACK test lead to the cathode of diode (Forward Bias) as shown in fig. Note the measurement and reading.
  4. Now reverse the test leads i.e. RED test lead to cathode and BLACK to anode (Reverse Bias) and note the reading and measurement displayed by multimeter.

Related Tutorial: How to test a battery with Test meter?

How to test LED (Light Emitting Diode)

Before testing a diode, we must identify the diode terminal i.e. anode and cathode. For LED, the longer terminal of diode is anode (+) and the shorter terminal is cathode (-). In other cases, the flat terminal of diode is cathode and the other side is anode as shown in below fig.

Related Post: How to Calculate the Battery Charging Time & Battery Charging Current – Example

How to test LED (Light Emitting Diode)
LED Terminals Identification (Anode & Cathode)

To test an LED with digital or analog multimeter, follow the instructions given below.

Related Post: How to Test & Fix the Printed Circuit Board (PCB) Defects?

How to test Zener Diode

Zener diode is something else as compared to normal diodes as simple PN junctions diodes operated in forward biased and not in reverse bias. The case is reverse in case of zener diode as it only operates in reverse based when the applied reverse voltage is greater than the zener breakdown voltage. This way, we need additional simple circuit to check whether the zener diode is good or bad.

How to Test a Zener Diode
Testing a Zener Diode by DMM & AMM

To check a zener diode with digital or analog multimeter, follow the instructions below.