Three Phase Continues Unbalanced Dual Element Electric Water Heater Thermostat Wiring
In our popular electric water heater wiring installation series, we will show three phase unbalanced and simultaneous electric heater thermostats and heating element wiring (480V or any other three phase voltage – NEC and 400V to 415V AC – IEC) in today’s post.
Difference Between 3 Phase Balanced and Unbalanced Water Heater
- Balanced 3 Phase Water Heater:
In balanced three phase wiring, all the hot wires (lines) carry equal supply (same magnitude of current and voltage). In case of star connection, the neutral carries zero current acting as a return path for current.
- Unbalanced 3 Phase Water Heater:
In this wiring, a single hot wire (line) provides supply to both heating elements through heater thermostat. The sum total of Neutral point is not zero i.e. it carries the net unbalanced current.
Related Posts:
- How to Wire 3-Phase Non-Simultaneous Water Heater Thermostat?
- How to Wire a Single Element Water Heater and Thermostat?
3-Phase Unbalanced Simultaneous Water Heater Thermostat Wiring
Simultaneous or continuous means both the upper and lower thermostats and heating elements are operational at the same time and doesn’t depend on each other as separate three phase supply has been provided to each heating element.
Keep in mind that both the lower and upper thermostats are ECO-protected i.e. both are the same. In this wiring connection from a three phase main panel, the Line 1 (Black) is connected to the L1 and L3 terminals of upper and lower thermostats respectively. Line 2 (Red) and Line 3 (Blue) are connected to the L3 of the upper thermostat and L1 of the lower thermostat respectively.
Upper heating element is connected through L4 and T2 terminals of the upper thermostat and the lower heating element is connected through L4 and T2 terminals of the lower thermostat.
This way, both heating elements are operational at the same time. The same wiring diagram can be used for three phase 480V AC or any other three phase voltage (US – NEC) or any other three phase supply and 3-Phase 400 – 415V AC (UK & EU – IEC). Note that we have used red, black and blue for three phase hot lines for illustration purposes only. You may follow your regional electrical codes and wiring colors.
Click image to enlarge
Related Posts:
- How to Wire 120V Simultaneous Water Heater Thermostat?
- How to Wire 120V Non-Simultaneous Water Heater Thermostat?
Wire and Breaker Size for Three Phase Electric Heaters
In our wiring tutorial, we have used 6 gauge wire for each hot wire. You may use the appropriate size cable / wire and right sized circuit breaker according to the heater rating. Check the user manual and nameplate data printed on thermostat and heating elements.
| Element Wattage | Phases | Circuit Breaker Size (Amp) | Copper Wire Size in Gauge | ||||||
| 208V | 240V | 277V | 480V | 208V | 240V | 277V | 480V | ||
| 3000W | 1 | 20 A | 20 A | 15 A | 15 A | 12 | 12 | 14 | 14 |
| 3 | 20 A | 20 A | – | 15 A | 12 | 12 | – | 14 | |
| 3800W | 1 | 25 A | 20 A | – | – | 10 | 10 | – | – |
| – | – | – | – | – | – | – | – | – | |
| 4000W | 1 | 25 A | 25 A | 20 A | 15 A | 10 | 10 | 12 | 14 |
| 3 | 25 A | 25 A | – | 15 A | 10 | 10 | – | 14 | |
| 4500W | 1 | 30 A | 25 A | 25 A | 15 A | 10 | 10 | 10 | 14 |
| 3 | 30 A | 25 A | – | 15 A | 10 | 10 | – | 14 | |
| 5000W | 1 | 30 A | 30 A | 25 A | 15 A | 10 | 10 | 10 | 14 |
| 3 | 30 A | 30 A | – | 15 A | 10 | 10 | – | 14 | |
| 5500W | 1 | 35 A | 30 A | 25 A | 15 A | 8 | 10 | 10 | 14 |
| 3 | 35 A | 30 A | – | 15 A | 8 | 10 | – | 14 | |
| 6000W | 1 | 40 A | 35 A | 30 A | 20 A | 8 | 8 | 10 | 12 |
| 3 | 35 A | 30 A | – | 15 A | 8 | 10 | – | 14 | |
| 8000W | 1 | 50 A | 45 A | 40 A | 25 A | 8 | 8 | 8 | 10 |
| 3 | 45 A | 40 A | – | 20 A | 8 | 8 | – | 12 | |
| 9000W | 1 | – | 50 A | 45 A | 25 A | – | 8 | 8 | 10 |
| 3 | 50 A | 45 A | – | 25 A | 8 | 8 | – | 10 | |
| 10000W | 1 | – | – | 50 A | 30 A | – | – | 8 | 10 |
| 3 | – | 50 A | – | 25 A | – | 8 | – | 10 | |
| 11000W | 1 | – | – | 50 A | 30 A | – | – | 8 | 10 |
| 3 | – | 50 A | – | 25 A | – | 8 | – | 10 | |
| 12000W | 1 | – | – | – | 35 A | – | – | – | 8 |
| 3 | – | – | – | 30 A | – | – | – | 10 | |
Related Posts:
- How to Wire 240V Water Heater Thermostat – Non-Continuous?
- How to Wire 240V Simultaneous Water Heater Thermostat?
Three Phase Wiring Color Codes – NEC & IEC
Other than NEC or IEC wiring color codes, you may use the local area codes applicable to your region.
NEC:
120V, 208V & 240 AC:
Black = Phase 1 or Line 1, Red = Line 2, Blue = Line 3, White / Gray = Neutral and Green/Yellow = Ground Wire
277V & Three Phase 480V
Brown = Phase 1 or Line 1, Orange = Line 2, Yellow = Line 3, Gray = Neutral and Green or bare conductor = Ground Wire
IEC:
Three Phase 400 to 415 AC:
Brown = Phase 1 or Line 1, Black = Line 2, Gray = Line 3, Blue = Neutral and Green = Earth Conductor
Related Posts:
- How to Toggle Electric Water Heater Between 120V and 240V?
- How to Control Electric Water Heater using Switches?
Warning:
- Disconnect the power before replacing, repairing, troubleshooting, maintenance and installation electrical appliances and equipment.
- Use the suitable voltage and ampere rating of switch with appropriate wire size and proper size of breaker according to the load rating.
- Failure to do so can result in electrical shock, serious injury, fire or even death.
- Please follow the manual instruction, local area codes or contact a licensed electrician for proper installation.
- The author will not be liable for any losses, injuries, or damages from the display or use of this information or if you try any circuit in the wrong format. So please! Be careful because it’s all about electricity and electricity is too dangerous.
Related Water Heater Wiring Diagrams
- How to Wire a Single Element Water Heater and Thermostat?
- How to Wire 120V Water Heater Thermostat – Non-Simultaneous?
- How to Wire 120V Simultaneous Water Heater Thermostat?
- How to Wire 240V Water Heater Thermostat – Non-Continuous?
- How to Wire 240V Simultaneous Water Heater Thermostat?
- How to Wire 3-Phase Simultaneous Water Heater Thermostat?
- How to Wire 3-Phase Non-Simultaneous Water Heater Thermostat?
- How to Toggle Electric Water Heater Between 120V and 240V?
- How to Wire 120V & 240V Main Panel? Breaker Box Installation
- How to Determine the Number of Circuit Breakers in a Panel Board?
- How to Size a Load Center, Panelboards and Distribution Board?
- How to Determine the Right Size Capacity of a Subpanel?
- Single Phase Electrical Wiring Installation in Home – NEC & IEC
- Three Phase Electrical Wiring Installation in Home – NEC & IEC
- How to Wire Auto & Manual Changeover & Transfer Switch – (1 & 3 Phase)
- Even More Residential Wiring Installation Tutorials

11 States Tighten Air Conditioner Rules Amid Heat Waves
How to Wire and Use Tesla Gen 3 Mobile Connector Charger
How to Wire 48A Level 2 Dual Port EV Charging Station
How to Wire Smart Electric Vehicle Charging Station – 32A/80A
How to Wire ChargePoint Home Flex Charger for Every EV
How to Wire an EV Wall Charger – Hardwired and Plug-in