NEC
-
Electrical Wiring
How to Size a Branch Circuit Conductors with Protection?
Sizing of Branch Circuits and Conductors with Protection Supplying from OPCD to the Final Load Point Branch Circuit According to NEC 100 – Definitions, branch circuits are the circuit conductors…
Read More » -
Electrical Wiring
How to Size Feeder Conductors with Overcurrent Protection
Sizing of Feeder Conductors with Protection Supplying from Main Panel to the Subpanel or Branch Circuits Feeder Conductors According to NEC 100 – Definitions, feeders are all circuit conductors between…
Read More » -
Electrical Wiring
How to Size Service-Entrance Conductors and Feeder Cables?
Sizing of Service-Entrance Conductors, Feeders and Service Disconnecting Means Service-entrance conductors for the service disconnect and main panel, as well as feeder cables for subpanels, must be properly sized in…
Read More » -
Lighting
How to Calculate the Floor Area For General Lighting?
Determining the Floor Area of a Dwelling Unit For General Lighting – Solved Example Based on NEC-2023 Sizing Floor Area for Lighting Determining the number of general lighting circuits in…
Read More » -
Lighting
How to Determine the Number of Lighting Branch Circuits?
How to Determine the Number of Lighting Branch Circuits for Dwelling and Non-Dwelling Units – NEC 2023/2026 According to NEC Article 100 – Definitions, a branch circuit refers to the…
Read More » -
Electrical Wiring
How to Determine the Number of Branch Circuits? – 3 Ways
How Many Branch Circuits Do You Need in a Dwelling Unit for Lighting Applications? 3-Methods with Examples Before determining the required number of circuits and associated calculations, let’s define and…
Read More » -
Basic Concepts
Why Do Americans Use Gas Kettles Instead of Electric Kettles?
Why Do People in the US Primarily Use Gas Stoves for Boiling, While Electric Kettles Are More Common in the UK and Europe? Americans tend to boil water on gas…
Read More » -
Power System
Why is the Neutral Wire Size Smaller than the Phase Wire?
Why is the Size of the Neutral Conductor Smaller than the Line Conductor in a Polyphase System? In a three-phase (poly-phase) system, the Neutral wire may sometimes be smaller than…
Read More » -
Protection
Why is the Ground Wire Size Smaller than the Hot Wire?
Why is the Size of the Ground Conductor Smaller than the Line Conductor? The ground wire does not always have to be the same size as the power (phase or…
Read More » -
Protection
Why Do We Need a GFCI & How Does it Protect During Faults?
Why Do We Need a GFCI Breaker and How Does it Protect During Ground Faults? A Ground Fault Circuit Interrupter (GFCI) is designed to protect circuits by detecting electrical faults…
Read More »