What is Voltage Stabilizer & How it Works?

What is Voltage Stabilizer. Difference between Stabilizer & Regulator

What is Voltage Stabilizer and Why we need it? Stabilizer Operation, Types and Applications Introduction to Stabilizer: The embedding of microprocessor chip technology and power electronic devices in the design of intelligent AC voltage stabilizers (or automatic voltage regulators (AVR)) led to produce high-quality, stable electric power supply in the event of significant and continuous deviation of mains voltage. As …

Read More »

All about MCB, its Construction, Working, Types & Applications.

What is MCB (Miniature Circuit Breaker), its Construction, Working, Types & Applications

What is MCB (Miniature Circuit Breaker), its Construction, Working, Types & How to select proper MCB for different loads rating? Introduction to Miniature Circuit Breakers (MCBs) All fuses need to be replaced when they have operated. Unlike a fuse, an MCB operates as automatic switch that opens in the event of excessive current flowing through the circuit and once the …

Read More »

How to Find the Size of Earth Conductor, Earthing Lead & Earth Electrodes?

How to Find the Size of Earth Conductor, Earthing Lead & Earth Electrode

Calculate the size of Earth Continuity Conductor, Earthing Lead & Earth Electrodes? For earhing or grounding purposes, the size of earth continuity conductor,, earthing lead and earth electrodes depend on wiring cables used in the system. Solved example given below will make the point easy to understand that how to determine the proper size of earth conductor, earth lead and …

Read More »

Difference Between MCB & MCCB According To IEC Standards

MCB or MCCB - Difference in IEC Standards - IEC 60898-1 & IEC 60947-2

MCB or MCCB – Difference in IEC Standards (IEC 60898-1 & IEC 60947-2) Circuit breakers are installed and used for safety purposes in both residential as well as commercial and industrial areas. In power distribution, we need circuit breakers at different levels. Depending on the current carrying capacity, breaking capacity and other functions, we select a suitable circuit breaker according …

Read More »

DC Drives – Construction, Working & Classification of Electrical DC Drives

DC Drives – Construction, Working & Classification of Electrical DC Drives

What are DC Drives? Working & Operation of DC Drives DC drive technology is efficient, reliable, cost effective, operator friendly and relatively easy to implement. DC drive provides many advantages over AC drives, especially for regenerative and high power applications. DC drives have been widely used in industrial drive applications in order to offer very precise control. Also read: Of …

Read More »

Electrical Drives – Classification of AC Drives & VFD

What are Electrical Drives? Working & Operation of AC Drives

What are Electrical Drives? Working & Operation of AC Drives Electrical drives are integral part of industrial and automation processes, particularly where precise control of speed of the motor is the prime requirement. In addition, all modern electric trains or locomotive systems have been powered by electrical drives. Robotics is another major area where adjustable speed drives offer precise speed …

Read More »

Different Types of Wiring Systems and Methods of Electrical Wiring

Electrical Wiring Systems. Cleat Wiring

Methods of Wiring And Different Types of Wiring Systems  Methods of Electrical Wiring Systems w.r.t Taking Connection Wiring (a process of connecting various accessories for distribution of electrical energy from supplier’s meter board to home appliances such as lamps, fans and other domestic appliances is known as Electrical Wiring) can be done using two methods which are Joint box system …

Read More »

What is the Difference Between Neutral, Ground and Earth?

What is the Difference Between Neutral, Ground and Earth

The Main difference between Neutral, Ground and Earth? ‪To understand the difference between Neutral, Ground and Earth, we must understand the need of these things first. Neutral Neutral is return path for an AC circuit which is supposed to carry current in normal condition. This current may be because of many reasons, primarily because of phase current imbalance and some …

Read More »

How to Read MCB Nameplate Data Rating Printed on it?

How to Read MCB Nameplate Data Rating Printed on it?

How to Read MCB Nameplate Rating? MCB (Miniature Circuit Breaker) is very common protection device (Such as fuse) used in domestic and industrial wiring and application and most of us have tried to buy MCB. It is very important device, which is to be procured with care. But when we use to visit shops or take advice of our “expert” …

Read More »

Earthing and Electrical Grounding Installation | A Complete Guide

Earthing, Grounding, Bonding, Types of Earthing, Grounding Installation

Earthing and Types of Electrical Earthing | Electrical Grounding Installation (Step by Step) Earthing, Grounding, Methods Of Earthing, Types of Earthing And Is Specifications In Respect To Earthing Of Electrical Installations What is Grounding or Earthing? To connect the metallic (conductive) Parts of an Electric appliance or installations to the earth (ground) is called Earthing or Grounding. In other words, …

Read More »