Protection

Why Don’t Bug Zappers and Fly Swatter Bats Kill Humans?

Do Mosquito Killer Rackets, Fly Swatter Bats, Bug Zappers, Etc., Harm a Person?

What is a Bug Zapper?

A big zapper is an electric device that uses a bait to attract the insects and electrocute them using a high voltage. There are two wire meshes that carry high voltage. When the insect drawn by the bait comes between the meshes, it is electrocuted with a spark and crackle. A bug zapper is also known as an electric fly swatter, electric fly killer, electric fly electrocution trap or more formally called an electrical discharge insect control system.

How Does a Bug Zapper Work?

There are different types of bug zappers being used. The basic working principle and circuit diagram of mosquito killer is shown in the previous post. However, all of them use the same principle to attract the insects and electrocute them. There are mainly two components

Bait

The bait is used to draw the insects. In earlier designs, meat was used to attract insects with incandescent bulbs. However, the design was too expensive for practical use. Therefore, the modern bug zapper uses ultraviolet light as they are attracted toward ultraviolet and yellow light.

Mosquitoes are generally attracted to carbon dioxide and the water vapor released in the breath of mammals. Therefore there are certain bug zapper that emits carbon dioxide.

Electrical Grid

There is an electrical grid that surrounds the bait. Usually, there is a non-electrical outer grid to prevent shocking any human. The electric grid is made of two meshes oppositely charged. When a mosquito comes into contact with them. The high voltage charge instantly flows through it causing it to burst with a spark.

Mosquito Killer Racket Circuit Diagram

This electric grid is charged up to 3kV to 9kV depending on its design.

Mosquito Killer Racket Charging Circuit

Related Posts:

Can Fly Swatter Bats Harm Humans?

The question arises does the bait i.e. the ultraviolet light harms our skin or does the high voltage electrical grid harm us? Both of them are explained briefly down below.

Why Don't Bug Zappers Harm Humans?

 

Is UV Light Harmful?

As we have earlier discussed, bug zapper emits ultraviolet light and we know ultraviolet light is harmful for our skin. That is why we use sunscreen, glasses, and a wide-brim hat to protect ourselves from the UV radiation of the sun on the beach.

Do not panic, the UV light emitted from the bug zapper is not dangerous. Actually, the black light emitted from bug zapper is near-ultraviolet light and is actually a fraction of what we are exposed to in our daily life. Studies suggest that these UV lights have been around for 80 years but there hasn’t been one single case.

Related Posts:

Can the Electric Grid Shock a Human Body?

The second question is that the electrical grid is charged up with very high voltage. And we know high voltage is dangerous as there are numerous “high voltage” signs used to keep people out of that area. So, can this electrical grid harm any person?

To better understand this problem one has to know about ideal voltage source and practical voltage source. The bug zapper is not an ideal source. It has very high voltage but it does not have enough power to provide current for a long time.

Sure the insect are instantly vaporized but that is due to their small body. The bug zapper can supply current in a few milliamps for a few microseconds which is enough for an insect. However, a person might feel a jolt for an instant before the voltage abruptly decreases.

It is not the voltage that kills but rather the prolonged current to deliver enough energy to stop a human heart. The bug zapper cannot provide sustained energy to stop a beating heart.

However, the tiny Electric spark generated between the electric grid can ignite any flammable liquid. Therefore, it should not come into contact with any flammable skin product or any other flammable surface.

To prevent touching the electrical grid, a plastic cage is placed on top of the electrical grid.

Health Risk of a Bug Zapper

Another health risk that goes unnoticed is during the electrocution of insects. The bug dies with a spark and burst into the air releasing thousands if not millions of germs. The air surrounding the bug zapper is contaminated with bacteria and viruses that can enter the human bloodstream through inhaling and by settling in our food.

Related Posts

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button