How to Calculate the Value of Resistor for LED’s & Different Types of LED Circuits

How to Find the Value of Resistor for Different Types of LEDs Circuits

The following step by step tutorial will help you to find the proper value of a resistor (or resistors) for one or more LEDs  and LEDs string circuits to design and connect with battery and power supply.

In the following guide, you will be able to learn how to:

Update: You can Also use this LED Resistor Calculator for the same purpose i.e. finding the value of exact or nearest standard value of resistor for LEDs circuits.

Related Posts:

Typical LED Symbol, Construction and Leads Identification

Click Image to enlarge

LED Diode Symbol, Construction & Leads Identification

Formula For Finding the Value of Resistor for an LED Circuit

Value of Resistor = (VSupply – VF) ÷ IF

Where:

The following formula can be used to calculate the value of power rating of the resistor.

Power Rating of Resistor = IF2 × Value of Resistor

Finding the Value of Resistor to Connect with an LED

Before we go into details, let’s try to evaluate the following simple circuit. This way, it will be easier to determine the value of resistors for other complex circuits.

Click Image to enlarge

LED-simple-circuit-ever.how-to-calculate-the-value-of-resistor-for-LED

Example:

In the above simple LED circuit, the supply voltage is 6V, LED forward voltage (VF) is 1.3 Volt and forward current (IF) is 10mA.

Now the value of resistor (which we will connect in series with LED) for the above circuit would be:

Resistor Value = (VSupply – VF) ÷ IF = (6 – 1.3) ÷ 10mA = 470 Ω

Current draw = 20mA

Resistor Power rating formula for this circuit

Resistor Power Rating = IF2 × Resistor’s Value

= (10mA) 2 × 470 Ω = 0.047W = 47mW

But this is the minimum required value of resistor to ensure that the resistor will not overheat, so it’s recommended that to double the power rating of the resistor that you have calculated, therefore, choose 0.047W × 2 = 0.094W = 94mW resistor for this circuit. Resistor power rating (Value is doubled) = 0.094 W = (94 mW)

Good to Know:

Related Posts:

Finding the Value of Resistor to Connect with LEDs in Series

Below is another simple LEDs (LEDs Connected in Series) Circuit. In this circuit, we have connected 6 LEDs in Series. Supply Voltage is 18V, The Forward Voltage (VF) of LEDs is 2V and the forward Current (IF) is 20mA each.

Formula:

Value of Resistor for LEDs in Series = (VSupply – (VF × No. of LEDs)) ÷ IF

Click Image to enlarge

Formula to find the value of resistor for series led circuit

Example:

In the above series LEDs string circuit, the total forward voltage (VF) of 6 LEDs = 2 × 6 = 12V

and forward Current (IF) is same (i.e. 20mA)

(Note: this is a series circuit, so current in series circuit in each point is same while voltages are additive) Now, the value of resistor (for series circuit) would be:

= (VSupply – (VF × No. of LEDs)) ÷ IF = (18 – (2 × 6)) ÷ 20mA

= (18 – 12) ÷ 20mA = 300 Ω

Total Current draw = 20mA

(This is series circuit, so currents are same)Resistor Power Rating

= IF2 × Resistor Value = (20mA) 2 × 300 Ω = 0.12 = 120mW

But this is the minimum required value of resistor to ensure that resistor will not explode. This way, it is recommended to double the value of power rating of the calculated resistor. therefore, choose 0.12W × 2 = 0.24W = 240mW resistor for this circuit. Resistor power rating (Value is doubled) = 0.24 W = (240 mW).

Finding the Value of Common Resistor to Connect with LEDs in Parallel

Click Image to enlarge

Formula for finding the value of resistors to connect LED’s in Parallel With Common Resistor

In this circuit, we have connected LEDs in parallel with a common resistor. Supply Voltage is 18V, The Forward Voltage (VF) of LEDs is 2V and the forward Current (IF) is 20mA each.

Formula:

Value of Common Resistor for LEDs in Parallel = (VSupply – VF) ÷ (IF × No. of LEDs)

Example:

Here, the total forward Current (IF) of 4 LEDs = 20mA × 4 = 0.08A, and forward Voltage (VF) is same (i.e. 2V)

(Note: this is a parallel circuit, so voltage is the same in each point while currents are additive).

Now, the value of resistor (for parallel Circuit with common resistor) would be:

= (Vsupply – VF) ÷ (IF × No. of LEDs)

= (18 – 2) ÷ 0.08

= 200 Ω

Total Current draw = 20mA × 4 = 80mA

(This is parallel circuit, so currents are additive)

Resistor Power Rating = IF2× Resistor Value= (20mA) 2 × 200Ω = 0.08 W = 80mW

As before, this is the least required value of resistor that will will not overheat and explode. Therefore, it’s recommended to double the power rating of the calculated resistor. This way, choose 1.28W × 2 = 2.56W resistor for this circuit. Resistor power rating (Value is doubled) = 2.56W (280 mW).

Finding the Value of Separate Resistor to Connect with LEDs in Parallel

Click Image to enlarge

Formula for finding the value of resistor(s) for connecting LED’s in Parallel With Separate resistor

This is another way to connect LEDs in parallel with separate resistors. In this circuit, we have connected 4 LEDs in parallel with separate resistors. Supply Voltage is 9V and the Forward Voltage (VF) of LEDs is 2V and the forward Current (IF) is 20mA each.

Formula:

Value of Separate Resistor for LEDs in Parallel = (VSupply – VF) ÷ IF

Example:

In this case, the total forward voltage (VF) of LEDs = 2 and forward Current (IF) 20mA (i.e. 20mA)

(Note: this is a parallel circuit, but we are finding the value of the resistor for each section, not for the whole circuit. So in each section, the circuit becomes in Series position (refer to the Series Circuit formula or the 1st simple circuit above, you will find that these are same)

Now, the value of resistor (for parallel Circuit with separate resistors) would be:

= (VSupply – VF)/ IF= (9 – 2) ÷ 20mA = 350 Ω

Total Current draw = 20mA × 4 = 80mA (This is parallel circuit, so currents are additive)

Resistor Power Rating = IF2 × Resistor Value= (20mA) 2 × 350 Ω = 0.14 = 140mW

Same like the above scenarios, the calculated value of the resistor is the minimum required value to safely connect in the LED circuit. To be on a safe side, it is recommended to double the power rating of the calculated resistor. Hence, choose 0.14W × 2 = 0.28W = 280mW resistor for this circuit. Resistor power rating (Value is doubled) = 0.28 W (280 mW).

There is another way to connect LEDs with batteries in series-parallel combination and yes, you will need a proper resistor(s) for that purpose too. But if you understand this simple calculation based tutorial, then I’m sure that you can easily determine the value of resistors for series-parallel combination based LEDs connections and circuits as well.

Related Posts:

↑