How to Wire Twin Timer for Repeated ON-Delay in Cycle Mode?

Wiring Digital Twin Timer in Repeated ON Delay Cycle Mode

In our previous wiring tutorial, we discussed how to wire a one-shot timer using a twin timer for delay. In today’s post, we will demonstrate how to wire the same digital timer for repeated cycle operation.

The twin timer can be used in two modes: one-shot operation or repeated operation viz.

One-Shot Mode:

In one-shot operation, when the predefined time setting expires, the connected load will be either ON or OFF permanently (based on OFF-delay or ON-delay circuit design). It means only a single operation is offered by the timer. For the second operation, the timer will have to be reset to the initial stage by turning off the power supply to the timer or momentarily connecting terminal 3 (RESET) and 4 (+12V).

Repeated Cycle Mode:

In the repeated cycle, as the name suggests, the ON and OFF operation of the circuit can be repeated, offering multiple operations instead of a one-shot operation, as mentioned above.

Related Posts:

How to Wire Twin Timer for Repeated ON-Delay in Cycle Mode

Suppose you need to design a circuit based on a digital twin timer for the following operations:

To do so,

  1. Set the timer in hours mode for both Time A and Time B.
  2. Set Time A for 00:10.
  3. Set Time B for 00:02.

Related Posts:

Working of the Twin Timer For Repeated ON-Delay Operation

  1. When the operator switches ON the circuit using a single-pole switch, it will turn on the light bulb (and remains ON until the two-way switch is switched OFF).
  2. The digital twin timer is activated, and the delay begins for 10 mins.
  3. When the delay period expires, the buzzer circuit activates and sounds for 20 sec.
  4. The second delay expires after 20 sec, and the buzzer turns off.
  5. As it is a repeated cycle circuit, the first delay time period starts again.
  6. The repeated cycle (in sequence) continues until the single-pole switch for the light is turned off. If so, the timer circuits reset to the initial state.

While wiring and configuring the circuit for repeated cycle operation using a twin timer, consider the following: