How to Wire Remote Control Countdown Timer?

Wiring Remote Control Countdown ON/OFF Delay Timer

Remote control countdown timers are versatile devices used in various applications, from lighting control to home automation and industrial processes. They allow you to set specific time intervals for turning on or off electrical devices remotely, providing convenience and energy-saving benefits. In this article, we will walk you through the process of wiring a remote control countdown timer (such as Woods 32555WD & TB/PA 318 etc.)  for ON and OFF Delay operations, enabling you to effectively manage your electrical devices with precision.

How to Wire 32555 Remote Control Plug-in with Timer?

In the following wiring diagram, we have used the Woods 32555WD wireless remote control plug-in with the AH3 timer to control the automatic ON and OFF operation of a recirculation pump.

As shown in the wiring circuit, the 32555 countdown timer is wired to a duplex outlet via a 120V AC supply. The 8-pin AH3-3 timer and the recirculation pump are connected via a three-pin plug inserted into the remote outlet.

This setup allows you to remotely control the ON-delay or OFF-delay operation of a circuit, such as a recirculation pump for hot water in the bathroom, or any other LED and CFL lighting points, etc.

  • The ON/OFF Delay time can be specified in the AH3 timer by rotating the knob to the specific time frame.
  • The wireless remote control grounded outlet can be wired for 120V, 8A, and a maximum of 1000 Watts.
  • In the case of tungsten and similar load types, the maximum load rating is 650 Watts at 6A and 120V.
  • The maximum range of operation for remote control is 100ft (30.5m).

How to Wire TB & PA-318 Wireless Countdown Timer?

In the following wiring circuit, we have used the TB-318 transmitter and the Skylink PA-318 receiver as a remote Plug-in ON/OFF control for a delay mechanism.

As shown in the figure, the PA-318 plug-in ON/OFF control receiver is wired to a duplex outlet via a 120V AC supply. The TB-318 wall switch remote transmitter is also used to wirelessly control the ON and OFF operations of the circuit.

Wiring 32555WD Remote Control ON-OFF Plug-in with Timer

A load point is connected to the grounded outlet of the PA-318 receiver via a 3-pin plug. To configure the circuit, let’s consider the following features before wiring the load points.

  • It can be used as ON/OFF control or countdown timer to delay the circuit operations.
  • The rating of max load for PA-318 is 1500 watts at 12.5A and 120V AC.
  • The max of 1/3hp (minimum 10W) inductive (such as motor) load can be connected to the transmitter.
  • It can be wired to control the delay from 1 minute to 60 minuets.
  • The max range of operation for remote control is 500ft (152m).

Countdown Timer Operation:

When the circuit is activated by providing the input signal to the receiver, the load will be switched on for a specified timeframe (set up in the device, e.g., from 1 up to 60 minutes). When the delay time expires, the circuit will turn off to save energy. This mechanism is known as OFF-Delay operation of the circuit.

Wiring TB-318 & PA-318 Wireless Countdown Timer

When the load circuit is operational in the ON/OFF mode, press and hold the “SET” button, and the RED LED will start flashing. The number of blinks indicates the timer setting in minutes, e.g.

Number of Blinking Timer Duration (In Mins)
1 1
2 5
3 15
4 30
5 60

ON/OFF Operation:

In this mode, the circuit will be switch ON or OFF when a proper input signal is received by the receiver from transmitter or other sources.

Related Posts:

➡️ READ FULL ARTICLE 📖

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.