Electrical Instruments/Measurements

Counter and Types of Electronic Counters

Counters and Types of Electronic Counters

What is Electronic Counter and Types of Counters What is Counter? A Counter is a digital logic device in computing to store and display the specific event continuously according to the configuration & programming. Sequential digital logic circuit is a common type of counter consist of single input line (Clock) and number of output lines. The value of output lines …

Read More »

Testing Electrical and Electronics Components and Devices with Multimeter

How To Test Electrical and Electronics Components with Multimeter

How To Test Electrical & Electronics Components with Multimeter? We all know the rule and importance of “Troubleshooting” in Electrical and Electronics Engineering. Most EE Components and Elements used in Electrical and Electronics Equipments, and Devices are common in their functions and operations. To be a good analyzer and troubleshooter, you must know the following basic techniques in Electrical and …

Read More »

Basic Electrical Engineering Tools and Their Uses

Electrical engineers are required to work in hazardous environments near energized equipment. There are certain tools they require to carry out their job effectively and safely without causing any harm to themselves and those around them. Here’s a sneak peek into some electrical engineering tools and their uses: Electronic Measuring Probes Current probes Current probes are one of the key …

Read More »

Electric Phase or Line Tester: Construction and Working

Phase or Line Tester Phase or Line Tester is a tool which is used to identify or test the Phase/Live/Hot or Positive wire/Conductor. Phase or Line Tester is also called Neon Screw Driver or Test Pin. (Good to Know: Phase, Line, Hot, Live and Positive are the same terms)   Construction of Phase or Line Tester Following are the main …

Read More »

Electrical Instruments/Measurements Library

 Electrical Instruments/Measurements Library How to Check a Capacitor with Digital (Multi meter) and Analog (AVO Meter). By Four (4) Methods with pictorial View. A Voltmeter, an ammeter (Ampere meter) and a battery cell are connected in series. It is observed that ammeter practically shows No Deflection. Why? Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple. …

Read More »

How to Test a Capacitor? 6 Ways to Check a Capacitor.

How to Test a Capacitor with Digital Multimeter and Analog AVO Meter. By six (6) Methods with pictorial View.

How to Test & Check a Capacitor with Digital Multimeter and Analog AVO Meter. By six (6) Methods with pictorial Views. In most electrical and electronics troubleshooting and repairing works, we face a common trouble that how to test and check a capacitor? Is it good, bad (dead), short or open? Here, we can check a capacitor with analog (AVO …

Read More »

A Voltmeter, an ammeter (Ampere meter) and a battery cell are connected in series. It is observed that ammeter practically shows No Deflection. Why?

 A Voltmeter, an ammeter (Ampere meter) and  a battery cell are connected in series. It is observed that ammeter practically shows No Deflection. Why? Due to the large resistance of the voltmeter, the circuit resistance becomes very high. As a result, very small current will flow in the circuit. this small current f on passing through the coil of voltmeter …

Read More »

Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple.

 Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple.Briefing: Her is our new simple Electrical/Electronics project about Automatic Street Light Control System.  it is a simple and powerful concept, which uses transistor (BC 547 NPN) as a switch to switch ON and OFF the street light system automatically. It automatically switches ON lights when the sunlight …

Read More »