How To
-
Part 6 – Sizing Motor Feeder Conductors and Cables
How to Determine the Correct Wire Size for Feeder Supplying Multiple Motors? In previous sections on motor circuit calculations, we determined conductor sizing, overcurrent protection, and overload protection with solved…
Read More » -
Part 5 – Sizing Motor Branch Circuit Conductors and Cables
How to Determine the Correct Wire Size for Motor Branch Circuit? Sizing Motor Branch Circuit Conductors Sizing the conductors for motor branch circuit is selected at 125% of the motor…
Read More » -
Part 4 – Calculating Locked Rotor Current (LRC) for Motors
How to Determine the Value of Locked-Rotor Current (LRC) for Induction Motors? What is Locked-Rotor Current (LRC)? Locked-rotor current (LRC) is the maximum starting current drawn by an electric motor…
Read More » -
Part 3 – Understanding NEMA Motor Nameplate Data and Marking
How to Read NEMA Motor Nameplates Data Printed on It for Motor Circuits? What is NEMA? NEMA (National Electrical Manufacturers Association) is a U.S.-based trade association that develops and publishes…
Read More » -
How to Size a Branch Circuit Conductors with Protection?
Sizing of Branch Circuits and Conductors with Protection Supplying from OPCD to the Final Load Point Branch Circuit According to NEC 100 – Definitions, branch circuits are the circuit conductors…
Read More » -
How to Size Feeder Conductors with Overcurrent Protection
Sizing of Feeder Conductors with Protection Supplying from Main Panel to the Subpanel or Branch Circuits Feeder Conductors According to NEC 100 – Definitions, feeders are all circuit conductors between…
Read More » -
How to Size Service-Entrance Conductors and Feeder Cables?
Sizing of Service-Entrance Conductors, Feeders and Service Disconnecting Means Service-entrance conductors for the service disconnect and main panel, as well as feeder cables for subpanels, must be properly sized in…
Read More » -
How to Size Equipment Grounding Conductor (EGC)?
What is Equipment Grounding Conductor? Sizing EGC for Grounding Systems The Equipment Grounding Conductor (EGC) is a main part of the electrical bonding and grounding system, ensuring the safe dissipation of…
Read More » -
How to Size Grounding Electrode Conductor (GEC)?
What is Grounding Electrode Conductor? Sizing GEC for Grounding in AC Systems For a proper grounding system, the following step-by-step guide can be used to determine the suitable size of…
Read More » -
Grounding and Methods of Earthing in PV Solar System
Methods of Earthing and Grounding in PV Solar Panel Systems Grounding (also known as earthing) is the process of physically connecting the metallic and exposed parts of a device to…
Read More »