1-Phase Circuits
Single Phase AC Circuits
-
How to Determine the Number of Nodes, Loops, Branches & Meshes in a Circuit?
What is Node, Branch, Loop and Mesh in an Electric Circuit, and How to Identify them? Understanding the fundamentals of electric circuits and networks is crucial for solving and analyzing…
Read More » -
Difference Between Linear and Nonlinear Circuits and Elements
What is the Difference Between Linear and Nonlinear Circuits Linear and nonlinear circuits are two different types of electrical systems. In this article, we are going to describe the key…
Read More » -
Three Phase Electrical Wiring Installation in Home – NEC & IEC
How to Wire 3-Phase Electrical Distribution Board & Consumer Unit in Home In our today electrical wiring installation tutorial, we will show how to wire and install a Three Phase…
Read More » -
How to Connect a Portable Generator to the Home Supply – 4 Methods
How to Wire a 1-P & 3-P Portable Generator to the Home Supply using Changeover & Without Changeover or Transfer Switch (ATS & MTS) for 230V/400V & 120V/240V We all…
Read More » -
How to Calculate the Suitable Capacitor Size in µ-Farads & kVAR for P.F Improvement
How to Find the Right Size Capacitor Bank Value in both kVAR and Microfarads for Power Factor Correction – 3 Methods As we got lots of emails and messages from…
Read More » -
How to Convert Capacitor μ-Farads to kVAR and Vice Versa? – For P.F Correction
How to Convert Capacitor kVAR to μ-Farads & Vice Versa for Power Factor Improvement? Conversion of kVAR to μ-Farad & μ-Farad to kVAR The following simple calculation tutorial shows how…
Read More » -
Sources and Causes of Low Power Factor
Causes and Sources of Poor Power Factor In an electrical power system, power factor is the ratio of the real power (kW) to the apparent power (kVA). A low power…
Read More » -
Power Factor Improvement Methods with their Advantages & Disadvantages
Different Methods Used for for Power Factor Correction The following devices and equipment are used for power factor improvement in an electrical system. Capacitor Banks: A bank of capacitors can…
Read More » -
Single Phase & Three Phase AC Circuits
Single Phase & Three Phase AC Circuits Library Three Phase Current Values in a 3-Phase System How to Calculate/Find the Rating of Transformer in kVA (Single Phase and Three Phase)?…
Read More » -
Disadvantages of Low Power Factor
What are the Disadvantages of Low Power Factor (P.F)? Power factor plays an important role in AC circuits as we know that power dissipation in three phase circuits Power in a…
Read More »