Differences between Active and Passive Filter

What is the Difference Between Active and Passive Filter?

Active filter and passive filter are both types of electronics filters that filter a specific frequency or a range of frequencies from a signal. Apart from frequency filtering, they are quite different in design as well as performance.

Before going into the differences between active and passive filters, let’s discuss their basics first.

What is a Filter

A filter is an electronic circuit that has the ability to pass or amplify a certain range of frequencies and block or attenuate other frequencies. They are used for filtering specific frequencies from a signal. Filters are used in signal processing such as removal of noise from a signal and extraction of a message from a signal etc.

There are different types of filters such as digital and analog filters, active and passive filters, linear and non-linear, low-pass, high pass, bandpass filters, etc. We are going to discuss the differences between the active and passive filters.

Difference between Active & Passive Filter

What is Active Filter?

Active filter is a type of filter that is designed using active components such as op-amp and transistor. They are used in combination with resistor and capacitor but not inductor. Such filters are capable of providing a power gain. However, their design is complex as compared to passive filters.

Non Inverting Low Pass Filter with Amplification

Since active filters use active components, they require an external power supply to operate. The filtered signal does not require amplification. Whereas the gain can be modified by varying a certain parameter during operation.

Op-Amp has very high input impedance and very low output impedance. Therefore, the active filter does not have loading effect problem at its source and load. Also, varying the load does not affect the performance of the filter because the load is isolated from the source.

The drawback of an active filter is the requirement of an external source. The filter’s performance depends on the external source’s health. The active components used in active filters have limited bandwidth. Therefore, they are not suitable for filtering high-frequency signals. They are also more susceptible to damage from large current.

Features of Active Filter

Related Posts:

What is Passive Filter?

Passive filter only uses passive components such as resistors, capacitors and inductors, etc. it has a very simple design and is very cheap. This filter does not require an external power source to operate and that is why they do not provide any power gain. However, they do use an inductor that makes them able to withstand high current.

RC Low Pass FilterThe passive components can handle very high frequency. As a result, passive filters are used for high-frequency applications. but they are not suitable for very low-frequency applications. The value of inductance must be increased which requires more bulkier inductor that also increases the size as well as the cost of the filter.

The load resistance is directly connected and affects the overall resistance of the filter. Therefore any change in the load resistor affects the electrical characteristics of the filter. It has limited input and output impedance, their performance is affected by loading affect.

Since passive components consume power from the input signal, the passive filter does not provide power gain and the output signal has a lower magnitude than the input. It requires amplification post-filtering.

Features of Passive Filter

Related Posts:

Key Differences between Active and passive Filter

Active Filter Passive Filter
Active filter uses active components such as Op-amp and transistor Passive filter uses passive components such as resistor, capacitor and inductor.
It requires external power source to operate It does not require an external power source.
It provides a high power gain It does not provide power gain.
It has a very high input impedance It has a medium input impedance.
It has a low output impedance It has a medium output impedance
Its characteristics do not change with change in load Its electrical characteristics vary significantly with changes in load.
It includes active as well as passive components except for the inductor. It is only made from passive components
It has frequency limitation due to limited bandwidth of op-amp It has no frequency limitations.
It does not have resonance problems They are affected by resonance
It has a high Q factor It has a low Q factor
They are expensive They are relatively cheaper
It cannot handle large current. It is stable and can withstand large current.
It has a complex design  It has a simple design
They are compact and have small size. Due to the use of inductor they are bulkier and heavy.

Comparison between Active and passive Filters

Power Source

Gain

Design

Loading Effect

Bandwidth

Size

Cost

Related Posts:

↑