Electrical Design
-
Electric Energy Cost Calculator – Cost of Energy Calculation
How to Calculate the Cost of Energy? Calculator & Examples Energy Cost Calculator The following calculator can be used to calculate the electric energy cost on a daily, monthly and…
Read More » -
Energy and Power Consumption Calculator – kWh Calculator
How to Calculate Power and Energy Consumption in kWh? Calculator & Examples Energy & Power Consumption Calculator in kWh Enter electric appliance in the dropdown menu or enter manual wattage…
Read More » -
Amps to Watts Calculator & Conversion – DC/AC (1 & 3 Phase)
How to Convert Amperes (A) to Watts (W)? Simple and Advanced Calculators You can use the following two calculators (Simple and Advance) to calculate the electric power in watts from…
Read More » -
Watts to Amps Calculator & Conversion – DC/AC (1 & 3 Phase)
How to Convert Watts (W) to Amperes (A) – Simple and Advanced Calculators The following two (basic and advanced) calculators can be used to calculate and convert the electric current…
Read More » -
Oersted’s Law of a Magnetic Field of a Straight Current Carrying Conductor
Oersted’s Law of Electromagnetism – Its Formula and Applications What is Oersted’s Law? A Danish physicist Hans Christian Ørsted discovered the relation between electricity and magnetism on 21 April 1820…
Read More » -
Right Hand Grip/Thumb Rule, Corkscrew Rule & End/Clock Rule
Right Hand Thumb Gripping Rule, Corkscrew Rule, Clock Rule or End Rule For Current & Magnetic Field Direction A Danish physicist Hans Christian Orsted in 1820 discovered the relation between…
Read More » -
Coulomb’s Laws of Magnetic Force – Formula & Solved Example
Coulomb’s Law of Magnetic Force Charles-Augustin de Coulomb was the first French physicist and military engineer who introduced the Laws of Magnetic Force in 1785 known as Coulomb’s Inverse Square…
Read More » -
Fleming’s Left Hand Rule and Fleming’s Right Hand Rule
Fleming’s Left and Right Hand Rules – What is the Difference? John Ambrose Fleming introduced these useful rules in the late 19th century which are applicable in magnetism and electromagnetism.…
Read More » -
Active and Passive Frequency Filters – Formulas & Equations
Frequency Filters – Active and Passive Filters Equations and Formulas Frequency Filters: Passive Filters The type of frequency selecting circuits that are made of only passive components such as resistor,…
Read More » -
Time Constant τ “Tau” Formulas for RC, RL & RLC Circuits
Time Constant τ “Tau” Equations for RC, RL and RLC Circuits Time constant also known as tau represented by the symbol of “τ” is a constant parameter of any capacitive…
Read More »