Capacitor
-
Basic Concepts
Why are Inductive & Capacitive Reactances Measured in Ohms?
Why are both Inductive and Capacitive Reactances Measured in Ohms instead of Farad, Henry or kVAR? In a DC circuit, there is no concept of inductive or capacitive reactance because…
Read More » -
Capacitors
What Happens If You Install a Larger Capacitor in a Fan?
Disadvantages of Using Higher Capacitance with AC Fans The primary function of a capacitor in a ceiling fan is to provide the necessary phase shift for starting torque and to…
Read More » -
Capacitors
Motor Capacitor Calculator – Calculate Fan Capacitor Value
How to Size a Fan Capacitor – Starting and Running Capacitors for Single Phase Motors Capacitor-start, capacitor-run motors use two capacitors viz a starting capacitor and a running capacitor. However,…
Read More » -
Capacitors
Why is a Capacitor Bank Rated in kVAR, Not in Farad?
Why is the Rating of a Capacitor Bank Expressed in kVAR Instead of Watt or Farad We know that a capacitor is rated in Farads because its capacitance value indicates…
Read More » -
Capacitors
Why is the Rating of a Capacitor Expressed in Farad?
Why is a Capacitor Rated in Farads rather than W, VA or Ah A capacitor stores electrical energy in the form of an electric field between its plates. The value…
Read More » -
Motors
Why is a Capacitor Needed for a Single-Phase Motor?
Why is a Single-Phase Motor Not Self-Starting? Necessity of Capacitors in 1-Phase Motors A capacitor is required for a single-phase motor to provide the necessary phase shift to start the…
Read More » -
Capacitors
Capacitor Color Codes – How To Read Capacitor Value? Calculator
How to know the Value of Capacitance of a Capacitor using Standard & Color Codes – Calculator & Examples Same like the resistor color codes, there are special indications like…
Read More » -
Capacitors
How to Measure Capacitance using a Multimeter?
Measurement of Capacitance with a Digital Multimeter To accurately measure the capacitance of a capacitor, you require expensive instruments such as an LCR meter which can measure Inductance (L), Capacitance…
Read More » -
Power Factor
Capacitor Bank in kVAR & µF Calculator for Power Factor Correction
How to Calculate the Capacitor Bank in kVAR & Microfarad for Power Factor Improvement? Calculator & Example Capacitor Bank Calculator The following Power factor improvement calculator will calculate the required…
Read More » -
Power Factor
Power Factor Correction Calculator – How to Find P.F Capacitor in µF & kVAR?
How to Calculate Capacitor in kVAR & µF for Power Factor Improvement? Calculator & Example Power Factor Calculator The following P.F calculator will calculate the existing or current power factor,…
Read More »







