Electrical Formulas
-
Formulas - Equations
Active and Passive Frequency Filters – Formulas & Equations
Frequency Filters – Active and Passive Filters Equations and Formulas Frequency Filters: Passive Filters The type of frequency selecting circuits that are made of only passive components such as resistor,…
Read More » -
Formulas - Equations
Time Constant τ “Tau” Formulas for RC, RL & RLC Circuits
Time Constant τ “Tau” Equations for RC, RL and RLC Circuits Time constant also known as tau represented by the symbol of “τ” is a constant parameter of any capacitive…
Read More » -
Formulas - Equations
Operational Amplifier (OP-AMP) – Formulas and Equations
Operational Amplifier (OP-AMP) Formulas Operational Amplifiers: Inverting Amplifier: The following terms are used in the formulas and equations for Operational Amplifies. Rf = Feedback resistor Rin = Input Resistor Vin = Input…
Read More » -
Formulas - Equations
Bipolar Junction Transistor (BJT) – Formulas and Equations
Formula & Equations for Bipolar Junction Transistor “BJT “ Bipolar Junction Transistor: Current Gains in BJT: There are two types of current gain in BJT i.e. α and β. Where…
Read More » -
Formulas - Equations
Diode Formulas & Equations – Zenner, Shockley & Rectifier
Shockley, Zenner & Diode Rectifier Formulas and Equations Diode Equation for I-V Curve The I-V curve (diode characteristic curve) can be find by the following no linear equations. This equation…
Read More » -
Formulas - Equations
Electric & Magnetic Flux, Density & Field Intensity Formulas
Electric Flux, Magnetic Flux, Electric Density, Magnetic Density, Electric Intensity and Magnetic Intensity Formulas & Equations Electric Flux Formula: Electric flux is the electric field lines passing through an area A.…
Read More » -
Formulas - Equations
Formula & Equations for Ohm’s, Kirchhoff’s & Coulomb’s Laws
Ohm’s Law, Kirchhoff’s Laws (KVL & KCL ) & Coulombs Laws Formulas & Equations Ohm’s Law Formulas Ohm’s law shows the relationship between current “I” & the voltage “V” where the…
Read More » -
Formulas - Equations
Equations & Formulas For RLC Circuits (Series & Parallel)
RLC Circuits – Series & Parallel Equations & Formulas RLC Circuit: When a resistor, inductor and capacitor are connected together in parallel or series combination, it operates as an oscillator…
Read More » -
Circuit Analysis
Voltage & Current Divider Rules (VDR & CDR) Equations
Voltage Divider Rule (VDR) & Current Divider Rule (CDR) Equations & Formulas Voltage division and current division are useful techniques which are used to express the voltage and current across…
Read More » -
Capacitors
Formula and Equations For Capacitor and Capacitance
Capacitor and Capacitance Formulas and Equations The following formulas and equations can be used to calculate the capacitance and related quantities of different shapes of capacitors as follow. Capacitance of…
Read More »