Analysis of a Simple R-L Circuit with AC and DC Supply

Analysis of a Simple R-L Circuit and Inductor Behavior

Analysis of a Simple R-L Circuit with DC Supply:

The circuit shown in Figures-1 is a simple R-L circuit (it has one simple resistor & inductor connected in series with a voltage supply of 2V); Though it is a simple circuit but if you will analyze it, your Electrical Engineering basics will be enhanced. First, we will analyze the circuit, when the DC voltage is applied. Can you find current in circuit-1; Answer is current I1=2 A. Its very simple, apply ohms law I=V/R; So, what is the role of an inductor in this circuit? Consider another circuit (Figure-2). Current in this circuit is also I2=2 A. So, you might be thinking again what is the role of the inductor?

Simple R-L Circuit 1
Figure-1 (circuit-1)
simple R-L Circuit 2
Figure-2 (circuit-2)

Answer is:

Conditions of circuit 1 at time zero
Figure-3
Conditions of circuit 1 at steady state
Figure-4
Time Response of a Simple R-L Circuit
Figure-5

Voltage equation of a simple R-L circuit (in case of DC) can be written as:

Voltage equation of a simple R-L circuit

(You can understand, in steady state current ‘i’ is constant hence its derivative is zero, so in steady state relation V = RI is followed by both circuit-1 & 2).

In Laplace form this voltage equation can be written as:

Laplace form

[In Laplace form, derivative (i.e. differentiation) is represented as ‘s’ and integration is represented as ‘1/s’. In the time domain, quantities are represented in small letters such as current can be expressed as ‘i(t)’ or ‘i’. In Laplace domain quantities are represented in capital letters, for example, current can be expressed as ‘I(s)’].

Above equation can be written as:

Transfer function of a simple R-L circuit

The standard form of a first-order transfer function is

Standard form of a first order transfer

So, you can understand simple R-L circuit is an example of a first-order transfer function. L/R is the time constant (you can find that unit of L/R is second).

We have derived the transfer function of a simple R-L circuit through voltage equation in which DC is applied, but this transfer function is valid for any type of input (i.e. AC also).

Now for circuit-1, R=1Ω, L=0.05 H, hence transfer function is:

equation_5

Its characteristics equation is ‘0.05s+1=0’; so its roots (poles of transfer function) is s=–20.

Now for circuit-2, R=1Ω, L=0.005 H, hence transfer function is:

equation_6

Its characteristics equation is ‘0.005s+1=0’; so its roots is s=–200.

You can understand, both the systems are stable, but pole of circuit-1 is near to the imaginary axis (Figure-6), hence lower stability in comparison to circuit-2; due to this reason transient period of system-1 is more.

Poles of both circuits
Figure-6

It was all about the important points of a simple R-L circuit.

Analysis of a Simple R-L Circuit with AC Supply

In the books of Electrical Engineering, you might have studied that

Reason of the first sentence, now you can understand. Suppose in the R-L circuit, AC is applied than inductor will behave as an open circuit in the starting. So, development of current requires some time, due to this reason, current lags behind the voltage in R-L, AC circuit.

In case of AC, in steady state, the inductor will offer reactance 2πfL; more will be the inductor value, more will be the transient period, and hence more the current will lag with respect to voltage.

In circuit-2, if AC is applied then, waveforms of input (voltage) and output (current) is shown in Figure-7

waveforms of input
Figure-7

It can be seen that voltage and current, both are started from zero, but the development of current is slow, it is lagging from the starting, so it is lagging in the steady state also.

How the waveform of Figure-7 is generated? It is generated with the help of MATLAB, the diagram is shown in Figure-8. With the help of this Figure, you can also generate these waveforms.

MATLAB Schematic
Figure-8

If you want to generate a waveform of current, against DC voltage, apply the step input instead of the sine wave. As the DC voltage is 2V in circuit-2, hence keep final value is equal to 2 in step input block (also keep step time=0); you may get the waveform as per the Figure-5.

Analysis of an Inductor Behavior:

In the books of Electrical Engineering, you might have studied that

We will give you an explanation of the first sentence here, it may enhance your Electrical Engineering basics. Consider the circuit shown in Figure-9:

Circuit 3
Figure-9

Values of current in steady state are I1=1A, I2=2A. Various polarities of voltages are shown. The voltage across the inductor is zero in steady state, but the polarity of voltage across the inductor is shown during the charging period. Suppose, the voltage source is disconnected, now what will happen?

In this case, the inductor will start discharging. Current through the inductor will decrease exponentially. The direction of current through inductor will remain the same, but voltage across inductor will change instantaneously. Current and voltage both will be reversed in 2Ω resistor immediately. Energy stored in the inductor will be dissipated in the air through I2R losses in both the resistors. Various conditions during discharging of the inductor is shown in Figure-10.

Conditions during discharging in circuit 3
Figure-10

So, we hope, explanation of the sentence “Current through inductor cannot change instantaneously” may be clear to you. You can see voltage across inductor is changed instantaneously (it is reversed immediately), but current continue to flow in same direction and slowly decreased to zero. In the case of resistor, current and voltage both can be changed or reversed instantaneously.

About the Author

Dr. Vipin Jain obtained degree of Bachelor of Engineering in 1992 from Nagpur University, Master of Technology in 2007, Ph.D. Degree in 2017 from University of Delhi. He has long teaching and industrial experience. He is a faculty member in the Electrical Engineering Department, Bharat Institute of Technology, Meerut (UP), India, since December 2007. More than twenty research papers have been published by him so far. He is energy auditor certified by Bureau of Energy Efficiency, Government of India.