How To
-
How to Wire a Three-Phase Meter? 400V & 120/208/240/277/347/480/600V – IEC & NEC
Installation of 3-Phase Energy Meter | 3-Φ, 4-Wires Electric Meter 400V & 120V/208V/240V/277V/347/480 & 600V AC Mains Supply & Service (From the Power Supply to The Main Distribution Board (MDB) &…
Read More » -
How to Control One Light Bulb from Five or Six Different Places? – IEC & NEC
Controlling a Lamp from Five or Six Locations using 4-Way Switches (US) or Intermediate Switches (3-Way) in EU. In today’s basic home electrical wiring installation tutorial, we will show how…
Read More » -
How to Control One Lamp From Three Different Places?
3-Way & 4-Way Switching Connections – Electrical Wiring Diagrams What is 2-Way & 3-Way Switching Circuits? Three-way switching or (Four-way circuits in the US) connection is used to control electrical…
Read More » -
Staircase Wiring Diagram – How to Control a Lamp from Two Places?
How to Control One Lamp from Two Different Locations using 2-Way & 3-Way Light Switches? In today’s basic electrical wiring installation tutorial, we will discuss the step-by-step method of staircase…
Read More » -
How to Control Each Lamp by Separately Switch in Parallel Lighting Circuit?
Controlling of Each Lamp by Independent Single way Switch in Parallel Lighting Circuit? In today basic home electrical wiring installation tutorial, we will show how to wire and control each…
Read More » -
How to Control a Light Bulb using Single-Pole (1-Way or 2-Way) Switch?
How to Wire a Light Switch using Single Pole Switch (AKA One Way (IEC) or 2-Way (NEC)? In today’s basic home electrical wiring installation tutorial, we will show how to…
Read More » -
How To Wire a Single Phase kWh Meter? 120V/240V & 230V AC – NEC & IEC
Installation of 1-Phase Energy Meter | 1-Φ, 2-Wires Electric Meter for 230V & 120V/240V AC Mains Supply & Service (From the Power Supply to The Main Distribution Board (MDB) & Load…
Read More » -
How to Wire Lights in Parallel?
How to Connect Light Points in Parallel ? The common household circuits used in electrical wiring installations are (and should be) arranged in parallel. Typically, switches, outlet receptacles, and lighting…
Read More » -
How To Wire Lights in Series?
How to Connect Lights Points in Series? In today’s basic electrical wiring installation tutorial, we will show how to wire lighting points in sires. Although, we know that series connection…
Read More » -
How To Wire Switches in Parallel?
How to Connect Two Switches in Parallel to Control a Single Load? In a previous basic home electrical wiring installation tutorial, we learned how to wire single way switches in…
Read More »







