Difference Between Electric and Magnetic Circuit

Differences between Magnetic and Electric Circuits

What is an Electric Circuit?

An electric circuit or network is a close loop path providing a return path to the flow of current. It is a closed conducting path in which current can flow from the source to the load. A general structure electric circuit can be a an AC or DC source connected to the load such as inductance, capacitance, resistance or other active and passive elements and parameters. Keep in mind that an electric can be open circuit as well.

What is a Magnetic Circuit?

A magnetic circuit is a closed path followed by magnetic flux (magnetic filed lines). A magnetic circuit can be made by using ferromagnetic material or other magnetic material having high permeability such as iron, cobalt, nickel, soft steel etc. These kind of circuit are mostly used in transformers, generators, motors, relay, coils and solenoid and measuring tools etc. A simple inductor or coil connected to the voltage source can make magnetic fields. Keep in mind that magnetic circuit is always a close loop circuit.

Related Post:

Difference Between Electric and Magnetic Circuit

There are some similarities and differences between magnetic and electric circuits. The following table shows a comparison between electric and magnetic circuits based on their definition, units, applicable laws and different analogies and term used for these circuits.

Related Posts:

Comparison between Electric and Magnetic Circuits

The following comparison table shows some differences between magnetic and electric circuits.

Characteristics Active Power Reactive Power
Definition A closed path where electric current flows through it is known as electric circuit. Rather than current flow, it can be an open circuit. A closed path where magnetic flux flows through it is known as magnetic circuit.
Current and Flux Current = EMF / Resistance

I = E / R or I = V / R

Flux = MMF / Reluctance

Φ = MMF / S

Current and Flux Density Current density (A/m2)

J = I / a

Flux density B (Wb/m2)

B = Φ / a

Intensity and Strength Electric field strength or electric filed intensity is the electromotive force (EMF) per unit electric charge. It is denoted by “E” and measured in volt/meter (V/m) or Newton/Coulomb (N/C).

• E = F / Q
• E = EMF / Q

Magnetic field strength or magnetic filed intensity is the magnetomotive force (MMF) per unit length. It is denoted by “H” and measured in Ampere-meter (A/m).

• H = NI/l
• H = MMF / l

Units The SI unit of I (Current) is Ampere (A). The unit if Φ (flux) is Weber (Wb) or Tesla (T).
EMF and MMF EMF (Volts “V”): Electromotive supplies energy in joules to each unit of coulomb charge and maintains potential difference or voltage.

• ε or E = W/Q
• E = V / I

Total EMF = IR1 + IR2 + IR3 … + IRn

 MMF (Ampere Turns “AT”): Magnetomotive is the pressure required to establish magnetic flux in a ferromagnetic material.

• ℱ = ΦR
• F = NI
• F = Hl

Total MMF = ΦS1 + ΦS2 + ΦS3 … + ΦSn

Conductivity and Permeability Conductivity

• G = I / Resistivity
• G = 1 / R

Permeability

• µ = 1 / Reluctivity
• µ = B / H

Where:

• B = Magnetic flux density
• H = Magnetic field intensity

Conductance and Permeance Conductance = 1 / Resistance. Conductance is the reciprocal of Resistance denoted by “G” and measured in Mho (℧) or Siemens.

G = 1 / R

Permeance = 1 / Reluctance. Permeance is the reciprocal of Reluctance denoted by “P” and measured in Weber per ampere turns.

P = 1 / S

Resistivity and Reluctivity Resistivity

ρ = RA/l

Reluctivity

S = I /aµ

Resistance and Reluctance In an electric circuit, resistance opposes the flow of electric current through it. It denoted by “R” and measured in ohms (Ω).

R = ρl/a

Where “ρ” is “rho” known as resistivity or specific resistance.

 

In a magnetic, reluctance opposes the flow if magnetic flux through it. It is denoted by “S” and measured in Ampere-Turn / Weber (AT/Wb).

• S = I /µa
• S = I /µoµra

Where

• µ is Permeability
• µr = Relative Permeability
• µo = Vacuum or space Permeability.

Variation in Resistance and Reluctance In an electric circuit, the value of Resistance (R) depends on the value of resistivity (ρ). So it is almost constant. A little change may occur due to change in the temperature. In a magnetic circuit, the value of reluctance (S) depends on the changes in value of B. So it is not a constant value.
Drop Voltage Drop = IR MMF Drops = ΦS
Direction of Electric and Magnetic Lines In an electric circuit, lies or electric current flow from positive to negative charge of polarities. In a magnetic circuit, lines of magnetic flux always flow from North to South Pole. (N Pole to S Pole).
Applicable Kirchhoff’s Laws Kirchhoff’s Current Law: KCL

• Ʃ I = 0 at a point or node

Kirchhoff’s Voltage Law: KVL

• Ʃ (IR) = Ʃ (EMF)

Kirchhoff’s Flux Law

• Ʃ Φ = 0 at a point or node

Kirchhoff’s MMF Law

• Ʃ (ΦS) = Ʃ (MMF)

Applicable Ohm’s Law • I = E / R
• I = EMF / R
• Φ = F / S
• Φ = MMF / S
Expandable Energy Energy is expandable as long as the electric current flows through the circuit and dissipated in the form of heat. Energy is not expandable as a small amount of energy is required in the initial stage to create flux in the magnetic circuit.
Insulation Rubber, glass, mica etc. are perfect examples of insulators for current flow in an electric circuit. There is no insulator as it can be set up in non magnetic materials such as air, glass, rubber etc.
Flow of Current and Flux Current flows in the form of electrons in an electric circuit. Flux does not flow but molecular poles are aligned in a magnetic circuit.