How to Measure Frequency using a Multimeter?

Measurement of Frequency with a Digital Multimeter

Frequency is the number of cycles completed in one second of time. There are different kinds of multimeters that can measure frequency. Alternating current and other electrical signals possess frequency that affects the operation of a device. By using a multimeter, we can measure multiple quantities such as voltage, current, resistance, capacitance, frequency temperature and continuity, etc and testing electrical and electronic components such as resistors, capacitors, diodes, transistors and cables & wires etc.

In this article, we are going to study how a multimeter measures frequency and what are the factors that affect its reading. 

How to Measure Frequency using Multimeter

Working Principle

A digital multimeter that can measure frequency has a peak-detection circuit. The meter measures the time between the two consecutive crests (peak of waveform) using the peak-detection circuit. it detects the peak of the input waveform and starts the timer. When the next peak of the waveform is detected, it stops the timer. The meter calculates the frequency using the time between the two crests of the waveform.

Related Posts:

Measuring Frequency

Any digital multimeter that can measure frequency has “Hz” written anywhere on the dial and upon the ports where probes are inserted. It may also share a spot on the dial with “VAC” or “V~”.

There are two methods for measuring frequency on a multimeter. If your multimeter has a dedicated spot on the dial, then follow this method.

Method 1

Frequency measurement

Frequency measurement 1

Related Posts:

Method 2:

Some multimeters have a separate button for “Hz”. For such meters, follow the following procedure.

Frequency measurement 3

Related Posts:

Problems Incurred during Frequency Measurement

There are many problems that can affect the frequency reading of a multimeter. We can reduce some of them to get an accurate reading.

Range of the Meter

The datasheet of a multimeter shows the lowest and highest frequency the meter can accurately measure. If the input frequency falls below the range, the multimeter may display a reading close to the actual reading but not accurate enough. The same thing will happen to a higher frequency above the range. The meters may not keep up with the actual frequency and display lower readings or show “OL” overload.

Therefore, it is necessary to know the range of the meter and the approximate frequency of the input signal.

Distortion in Input Signal

If the input signal has frequency distortion, it can affect the reading of the multimeter and cause uncertainty in the reading. The reading may also fluctuate. The signal can be filtered from noise by using a low pass filter.

Related Posts:

Signal Radiation

Sometimes, the multimeter may pick up the frequency reading without probes touching the line. it may occur due to the unshielded lines that act as antennas to radiate the EMI (Electromagnetic interference). The meter picks up the signal, amplify and measure It and display the reading. It may or may not be accurate. Therefore, it is best to physically connect the probes to the wire.

Why do We Measure Frequency?

Measuring frequency is important because circuits and machines are designed to operate at specific frequencies. They either operate at fixed frequency or variable frequency where the output depends on it.    

One such example is an AC electric motor whose speed is directly proportional to the frequency of the mains supply. A motor or transformer designed to operate at 50 Hz will run at a higher speed if connected to a 60 Hz supply. Similarly, a 60 Hz motor and transformer will be slower if it runs on a 50Hz supply. Here is an interesting question for you :) Is it Possible to Operate a 50Hz Transformer on 5Hz or 500Hz Frequency?.

Good to Know: Frequency can’t be measured using an Analog Multimeter. Only dedicated digital multimeters with specific features (like dedicated Auto Hz button or separate Com terminal) can be used to measure frequency in different ranges even up to 100kHz or more.