How to Measure Voltage using Digital and Analog Multimeter?
Measurement of AC and DC Voltage with a Multimeter – (DMM + Analog) Voltage measurement is one of the simplest and easiest tasks to perform with a DMM (digital multimeter)…
Read More » -
How to Measure Current using Digital and Analog Multimeter?
Measuring of AC and DC Current with a Multimeter? (DMM + Analog) Just like voltage, current measurement is also necessary for troubleshooting any circuit. It is used to check if…
Read More » -
How to Wire a Subpanel? Main Lug Installation for 120V/240V
Wiring a Subpanel for 120V & 240V with GFCI – NEC – US What is a Main Panel? According to NEC (National Electric Code: Article 1 00-Definitions), a Main Panel…
Read More » -
How to Wire a Twin 3-Pin Socket Outlet? Wiring 2-Gang Socket
How to Connect a 2-Gang, 3-Pin BS1363 Socket Outlet? Wiring Switched Double Plug Socket 3-Pin Dual Socket Outlet A BS1363 socket outlet (by IEC) is also known as a UK…
Read More » -
How to Wire a UK 3-Pin Plug? Wiring a BS1363 Plug
Wiring a BS1363, 3-Pin Plug Safely and Correctly What is a UK 3-Pin Plug? A UK plug, also known as a British Plug, Type G Plug, or BS1363 Standard Plug…
Read More » -
How to Wire a Garage Consumer Unit?
Wiring a Garage Consumer Unit with RCD & Connecting 1-Φ, 230V Load Points in it. What is a Garage Consumer Unit? A Garage Consumer is a type of consumer unit…
Read More » -
AWG/SWG to mm/mm2, inch/inch2 & kcmil Calculator & Conversion
AWG and SWG Size Conversion Calculator with Formula, Chart & Table Standard Wire Gauge “SWG” Calculator The following American Wire Gauge “AWG” and Standard Wire Gauge “SWG” calculators will calculate…
Read More » -
Standard Wire Gauge “SWG” Calculator – SWG Size Chart & Table
SWG “Standard Wire Gauge” Size Calculator & Cable Properties Table & Chart Standard Wire Gauge “SWG” Calculator The following Standard Wire Gauge (SWG) calculator will calculate the diameter in inches,…
Read More » -
American Wire Gauge “AWG” Calculator – AWG Size Chart & Table
AWG “American Wire Gauge” Size Calculator & Cable Properties Table & Chart American Wire Gauge “AWG” Calculator The following American Wire Gauge (AWG) calculator will calculate the diameter in mm,…
Read More » -
What Happens if We Connect a Polar Capacitor the Wrong Way?
What Happens When You Connect an Electrolytic Polarized Capacitor in The Reverse Polarity? There are different types of capacitors such as polar (fixed capacitors e.g. electrolytic, Pseudo-capacitors, ELDs, and super-capacitors)…
Read More »