Troubleshooting
-
What happens if You Connect a 3-Φ Induction Motor to 1-Phase Supply?
What will happen to the 3-Φ (400V) Induction Motor If Connected to 1-Phase (230V) Supply? As the name suggests, a 3-phase induction motor must be connected to the three phases…
Read More » -
What happens to the 3-Phase Motor When 2 Out of 3 Phases are Lost?
What will happen to the 3-Φ Induction Motor Incase of Failure of 2 of the 3-Phases? When a linear or balanced load is connected to the 3-Φ supply system, the…
Read More » -
What happens to the 3-Phase Motor When 1 Out of 3 Phases is Lost?
What will happen to the 3-Φ Induction Motor Incase of Failure of 1 of the 3-Phases? A three phase induction motor must be connected to all the three phases for…
Read More » -
Hopkinson’s Test – Circuit Diagram, Working and Applications
What is Hopkinson’s Test? Its Circuit Diagram and Operation in Motor Generator Set & Coupling What is Hopkinson’s Test? A Hopkinson Test is used to identify the efficiency of two…
Read More » -
What is Multimeter? Working of Analog and Digital Multimeters
What is Multimeter? Types, Functions Working and Applications Electrical and electronics engineering students, engineers and technicians use various kinds of measurement devices to check various electrical quantities in a circuit…
Read More » -
Tripping Curves of Circuit Breakers – B, C, D, K and Z Trip Curve
Types of Circuit Breaker Based on its Tripping Curve A circuit breaker is a protection device employed in every electrical circuit to prevent any potential hazard. There are different types…
Read More » -
How to Measure Capacitance using a Multimeter?
Measurement of Capacitance with a Digital Multimeter To accurately measure the capacitance of a capacitor, you require expensive instruments such as an LCR meter which can measure Inductance (L), Capacitance…
Read More » -
How to Measure Frequency using a Multimeter?
Measurement of Frequency with a Digital Multimeter Frequency is the number of cycles completed in one second of time. There are different kinds of multimeters that can measure frequency. Alternating…
Read More » -
How to Measure Power using Digital and Analog Multimeter?
Measurement of Electric Power with a Multimeter? (DMM – Analog Meter) A multimeter is a very essential tool for electrical and electronics engineers, technicians, electricians, students and hobbyists. It can…
Read More » -
How to Measure Resistance using Digital & Analog Multimeter?
Measuring Resistance with a Multimeter? (DMM – Analog Meter) Measuring resistance just like voltage and current is an important part of troubleshooting any component. It tells the condition of the…
Read More »