Circuit Analysis
-
Circuit Analysis
Tellegen’s Theorem – Solved Examples & MATLAB Simulation
Tellegen’s Theorem – Step by Step Guide with Solved Examples What is Tellegen’s Theorem? Tellegen’s theorem was published by a Dutch electrical engineer and inventor Bernard D.H. Tellegen in 1952.…
Read More » -
Circuit Analysis
Analysis of a Simple R-L Circuit with AC and DC Supply
Analysis of a Simple R-L Circuit and Inductor Behavior Analysis of a Simple R-L Circuit with DC Supply: The circuit shown in Figures-1 is a simple R-L circuit (it has…
Read More » -
Circuit Analysis
Maximum Power Transfer Theorem for AC and DC Circuits
Maximum Power Transfer Theorem for AC & DC Circuits – Solved Examples Introduction to Maximum Power Transfer Theorem Very often we come across various real time circuits that works based…
Read More » -
Circuit Analysis
Kirchhoff’s Current & Voltage Law (KCL & KVL) | Solved Example
KCL & KVL – Kirchhoff’s First & Second Laws with Solved Example A German Physicist “Robert Kirchhoff” introduced two important electrical laws in 1847 by which, we can easily find…
Read More » -
Circuit Analysis
SUPERNODE Circuit Analysis | Step by Step with Solved Example
Supernode Analysis – Statement, Formula and Step by Step Solved Example What is Supernode Analysis? Today, we will try to answer the common question of why we use Supernode circuit analysis while…
Read More » -
Electrical Design
10+ Online Circuit Design & Simulation Tools for Electrical & Electronics Engineers
Free Online Electrical & Electronics Circuit Design, Analyzing and Simulation Tools Hi folks! As you may recall, we’ve previously shared an article about Android apps for electrical and electronics engineers,…
Read More » -
EE Calculators
Electrical and Electronic Engineering Calculators
Electrical & Electronics Engineering Online Calculators Electrical Wire & Cable Size Calculator (Copper & Aluminum) NEC Wire Size Calculator in AWG – Cu & Al …
Read More » -
Capacitors
Series Capacitor Calculator
Capacitance of Capacitors in Series Calculator Formula & Equations for Series Capacitors Calculator Finding Total Series Capacitance (CT) when C1 and C2 Given; 1/CT = 1/C1 + 1/C2CT = C1||C2 CT = C1 x C2 / (C1 + C2)…
Read More » -
EE Calculators
Parallel Inductors Calculator
Inductance of Parallel Connected Inductors Calculator Formula & Equations for Parallel Inductors Calculator Finding Total Inductance (LT) when L1 and L2 are given; 1/LT = 1/L1 + 1/L2 LT = L1||L2 LT = L1 x L2 /…
Read More » -
EE Calculators
Parallel Resistors Calculator
Resistance of Parallel Connected Resistors Calculator Formula & Equations for Parallel Resistors Calculator Finding Total Resistance (RT) when R1 and R2 are given; 1/RT = 1/R1 + 1/R2 RT = R1||R2 RT = R1 x…
Read More »