Automatic Street Light Control Circuit using LDR & Transistor BC 547

Basic Electronic Project – Automatic Street Light Control Circuit

Following is yet another simple Electrical/Electronics project for automatic street light control systems especially for students, newbies and hobbyists.

Features:

Related Simple Projects:

Advantages:

Enough … Now let’s begin the step by step guide to make the circuit of the basic project.

Components Required:

Related Post: Magnet levitation simple Electrical Project

Procedure

Related Post: Mini Air-Cooler System from 12V Fan (Homemade form Trash)

 

The simple circuit is ready for testing now. Connect 6V to 9V battery terminals to the circuit as shown in fig and see the output. As you block light falling on the Light dependent resistor(LDR), the LED glows and vice versa.

LED GLOWS EVEN IN LESS DARKNESS. Use torch light or lighter if the LED glows in less darkness. In addition, you can try to adjust the sensitivity of this circuit by using a variable resistor in place of R1-300 Ohm. You may use other resistances as well, (e.g., 1KΩ, 10KΩ and 100KΩ, etc.)

Pictorial Story: (Click images to enlarge)

Components & Schematic Circuit Diagrams for Automatic Street Light Control System

Automatic-Street-Light-Control-System

Circuit Diagram 1. Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.). We have tried and Cicuit#1 in this  tutorial but you may also try the second one (Circuit#2) mentioned below ight after circuit no 1.

Automatic Street Light Control Circuit using LDR & Transistor

Circuit Diagram 2 . Automatic Street Light Control System using LDR and two nos. of Transistor BC 547.

Dark Detector Circuit for Automatic Street Light Control using BC547 Transistor and LDR

Automatic-Street-Light-Control-System.-2528Sensor-using-LDR-2526-Transistor-BC-547.-2529-Very-SimpleAutomatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple.

Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple. Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple.
Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple.
Whenever light falls on the LDR (Light Dependent resistor), the LED is OFF i.e. the LED does not glow.

Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple.

In the dark (e.g. when light is blocked to the LDR), the LED is ON i.e. the LED is ON.

Snapshot taken out from the Video.

Automatic Street Light Control System.(Sensor using LDR & Transistor BC 547.) Very Simple.

For more basic electrical and electronics engineering project tutorials, visit: Simple Electrical & Electronics Projects Library

Some Basic Electronic Projects Circuit Diagrams based on LDR

Exit mobile version