How to Measure Resistance using Digital & Analog Multimeter?

Measuring Resistance with a Multimeter? (DMM – Analog Meter)

Measuring resistance just like voltage and current is an important part of troubleshooting any component. It tells the condition of the components. The resistance measurement is also used to check for open or closed circuits. Last but not least you can check how accurate the resistors are since they are also color-coded.

Related Posts:

What is Resistance?

Resistance is the opposition to the flow of current. The device that is used for measuring the resistance is called Ohmmeter. Ohmmeter has a voltage across its both terminals that flow the current through the component being tested. If the resistance is very high it means the low current will flow. If the resistance is low it means the current flowing will be high. Based on the amount of current flowing, it determines the resistance.

We can also utilize the resistance readings to determine a short circuit or a broken circuit. In this multimeter tutorial, we will measure the resistance using DMM and analog multimeter with step by step guide. Before you go to follow the steps, you may know the basic difference between AC and DC resistance.

How to Measure Resistance using Digital & Analog Multimeter?

Related Posts:

Measuring Resistance using Digital Multimeter:

DMM Resistance Measurement Mode Selection

DMM Resistance Measurement Range Selection

DMM Resistance Measurement Socket

DMM Resistance Measurement ReadingThe given 1K Ohm resistor’s measurement shows 1004 Ohm resistance which is more accurate as the 4th color band (gold) shows tolerance of 5%

Note: Do not measure the resistance of a circuit with power still ON. Look out for capacitors in a circuit before testing a component. The components in parallel also affects the equivalent resistance. make sure the component being tested does not have any other component in parallel. Do not touch the tip of the leads while measuring, it will inflict error in the reading.

Related Posts:

Measuring Resistance using Analog Multimeter:

Analog multimeter has the same procedure. However, it has a little calibration to perform while measuring resistance.

Analog Multimeter Resistance Measurement Mode selection

Analog Multimeter Resistance Measurement Range Selection

Note: The analog multimeter resistance range has multiplying factors. For example, x1, x10 and x100 are different ranges showing the scale value multiplying by the factor to get the actual reading.

Analog Multimeter Resistance Measurement Sockets

Analog Multimeter Resistance Measurement Zero Adjustment

Analog Multimeter Resistance Measurement Scale Reading

Related Posts:

Factor Affecting Resistance Readings

The resistance can be affected by many factors. Therefore, while measuring resistance the following factors must be considered:

Component in a circuit: If the component is inside a circuit, its resistance can be affected by any other components in parallel.

Power through the circuit: if there is power supplied to the circuit or any charged capacitor, it will affect the readings since the ohmmeter works on the basis of current flowing through the meter.

Diode in a circuit: If there is a diode in a circuit, the resistance of the circuit will vary if the probes are swapped with each other. it is due to the fact that the diode does not allow current in one direction.

Fingers touching the leads: if your fingers are touching the leads, it will affect the reading due to the leakage of some current through your body. Do not touch the tip of the leads while measuring resistance.

Temperature: Most component’s temperature rise when current passes through them. It is best not to measure the resistance when they are hot because the temperature affects the resistance.

Related Posts:

Powered ON Circuit

Always make sure there is no power supplied to the circuit. it not only affects the readings of the resistance but also the high voltage will damage the multimeter as well.

Relative, Zero or Delta Mode

Modern DMM has “REL” mode short for relative mode which is also known as zero or delta mode. It is used for measuring very small resistance. In this mode, the resistance of the probes is automatically subtracted from the reading. When the probes are shorted together, it should show 0 ohms.

Zero Adjustment of Analog Multimeter

The zero calibration or zero adjustments is a very important step before measuring resistance using an analog multimeter. When the probe leads are shorted together, it should provide full-scale deflection (FSD) meaning zero ohm resistance between the leads.

Analog Multimeter Resistance Measurement Zero Adjustment

If there is no FSD i.e. it shows some resistance, it must be eliminated by turning the zero control knob to move the needle go all the way to FSD.

It is also affected by varying the range of the meter. Therefore, whenever you change the range of the meter, zero calibration must be performed.

If you are unable to get FSD even after connecting the probes together and turning the zero control, the multimeter battery is depleted and needs to be replaced. 

Battery Depletion

Unlike voltage and current measurement, the resistance measurement consumes the battery inside the meter. Therefore, if the battery is depleted, it will affect the reading. The DMM show clear indications for low battery and it will also show high resistance between its probes. However, an analog multimeter does not have such indications. Instead, if it does not show FSD when connecting the probes together, the battery is low and must be replaced.

Related Multimeter Tutorials:

↑