Which Carries More Current: a Solid Conductor or a Stranded Conductor?
The debate among electricians in the United States and Europe over solid wire versus stranded wire is ongoing, and there is no definitive winner. It is not possible to declare one type universally superior, as each offers specific advantages and disadvantages depending on the application.
In the following article, we will differentiate between solid and stranded conductors to help you determine the most suitable option for specific application based on factors such as flexibility, ease of routing, mechanical protection requirements, transmission distance, installation environment (indoor or outdoor), cost, and current-carrying capacity (ampacity).
What is Stranded Wire?
A stranded wire is a bundle of multiple thin strands of conductors (twisted-pair in insulation). They are available in different sizes for specific applications. For example, in old days, the size of wire in UK was 3/0.029″, 7/0.036″, 7/0.042″ where the first digit (e.g. 3 or 7 shows the number of stranded conductors and the second part of numbers (e.g. 0.029″, 0.042″ shows the size of the conductor i.e. 0.036″ means 0.036 inches2).
Now, they opted to the IEC where the conductor size (Table 12) is selected from 1.5 mm2 to 240 mm2 for different applications. On the other hand, the size of wire in the US is 7/32 where the number of “7” shows the number of strands where 32 shows the AWG size of conductor. For solid and other conductors, they use America Wire Gauge Size from 0000 (4/0) to 40.
Stranded wire offers flexibility as compared to solid wire thus the suitable option for electrician stranded wire in applications where wires need to be bent or twisted as it is easier to route through pipes and conduit in walls. In addition, current flows safely in the stranded wire as the heat generated in the wire conductor (due to flow of current) can be easily dissipated as there is air-gap among the stands of conductors.
The stranded wire is also used in applications of repetitive motion such as opening/closing the doors etc. These are the better choice in case of short distance and easily can be fitted in patch cords.
You may also notice the stranded wire instead of solid wire for power transmission and distribution lines which is used to reduce the skin effect (a property of alternating current (AC) flowing on the outer surface of the conductor instead of the whole conductor). To eliminate the skin effect, stranded wire is the appropriate solution to do so.
On the other hand, stranded wires are costly, faces corrosion problems especially in humidity and outdoor applications. Finally, the ampacity of stranded wire is lesser as compared to the same size of solid wire as there is air gap between the conductors in case of stranded wires.
Advantages of Stranded Wire
- More flexibility
- Easy routing & bending with longer flex life in motion applications
- Less heating & safe current flow
- suitable for crimp termination & patch cords connection
- Less skin effect in case of longer and high voltage and power transmission
Disadvantages of Stranded Wire
- High chance of corrosion especially in outdoor applications
- Less current capacity as compared to the solid conductor having the same size.
- More voltage drop
- Noisy sound with attenuation of 20-50% and medium transmission performance of high frequencies
- Complex termination and connection
- Costly as compared to solid wire
What is Solid Wire?
As the name suggests, a single solid conductor covered in insulation which is thicker and heavier than stranded wire is known as solid wire. As we know that stranded wire has some advantages over solid wire but still it is used in home wiring especially in US for 120/240 main panel and its applications for some reasons like better connection and higher ampacity etc.
The current carrying capacity of solid wire is more than the stranded wire due to the air-gaps between the conductors. It has less resistance due to the thickness of the conductor and offers perfect termination and connection.
In addition, solid wire has more capacity and there is less voltage drop, less corrosion, lossless sound (less noise ratio), more long lasting and stable connection. Moreover, solid wires are less costly and suitable in outdoor applications.
On the other hand, solid wire has less flexibility and it is difficult to bend and twist the wire due to its stiffness. So it might damage and break the solid wire if used with multiple bending and routing especially in movement based applications.
Advantages of Solid Wire
- Perfect termination and connection
- High ampacity as compared to stranded wire having the same size.
- Clear sound (less noise due to low attenuation) and good transmission performance with high frequencies
- Lesser resistance and anti-corrosive in indoor/outdoor applications
- low voltage drop and suitable for long distance applications
- Less costly as compared to stranded wires.
Disadvantages of Solid Wire
- Less flexible
- Might damage the cable if used in repetitive motion applications
- Problems of skin effect in case of high voltage and power transmission lines
- Not suable in electronics, digital communication and computer applications
The following table shows the differences and comparison between solid conductor and stranded conductor in accordance with special conditions and applications.
Current Carrying Capacity of Solid & Stranded Wire
If the diameter of both wires are the same, the solid wire will carry more current than the stranded wire. This is because the cross sectional area of the solid wire is bigger than the stranded wire as there is air-gap between the strands of the conductor in it. For this reason, an electrician must select an appropriate wire size based on the wire gauge and ampacity for desired application.
One another phenomenon known as skin effect (current flowing on the outer surface of the conductor instead of the whole conductor) occurs in AC current having frequency. That’s the reason they use stranded wires for high power transmission. But skin depth may be neglected in case of copper wire (up to 6mm) used for home wiring having the frequency of 50/60 Hz.
Which One is Better – Solid or Stranded Wire & Why?
You must select a wire and cable type based on initial & long term cost, indoor/outdoor & specific applications, load types, motion, right ampacity and other weather & environmental factors etc. As a conclusion, the selection of solid wire vs stranded wire depends on multiple factors. In short:
If you need durability, simplicity, smoothness and especially cost effective solution based on your required applications, Solid wire is for you.
If you are looking for long term flexibility and special motion based applications, stranded wire is the best choice for you then.
Related Posts:
- Wire Nut vs WAGO Connector: Which One is Better and Why?
- Why Does Japan Use Both 50Hz and 60Hz in Its Power System?
- Why Do Americans Use Gas Kettles Instead of Electric Kettles?
- Difference Between 15-Amp and 20-Amp Outlet?
- Difference Between NEMA 14-50 Standard Vs EV Receptacle
- What are the Tiny Cylinder in Power Cords & Cable?
- Why Coaxial Cables are Highly Insulated?
- How To Locate Faults In Cables? Cable Faults, Types & Causes
- Submarine Cables – Construction, Characteristics, Cables Laying & Joints
- Choice of Wiring System – Types Of Cables Used In Internal Wiring


How to Wire a Smart Breaker in a Smart 120/240V Panel
How to Wire 120/240V Smart Load Center with Smart Breakers
Why are the Breakers Switched Opposite to Light Switches?
Difference Between CTL and Non-CTL Breakers & Load Centers
Can I Use a Different Brand Breaker in a Panel if it Fits?
Difference Between Specified & Classified Circuit Breakers