Motors
-
No-load Test of Induction Motor & Block Rotor Test of Motor
What is No Load Test of an Induction Motor and Block Rotor Test of Electric Motors? The circuit model of an induction motor is similar to the transformer. Therefore, the…
Read More » -
What is a Linear Induction Motor “LIM”? Working Principle and Applications
Linear Induction Motor (LIM): Operating Principle, Classification, Performance, Advantages, Disadvantages and Applications What is a Linear Induction Motor? The induction motor is used to convert the electrical energy into rotation…
Read More » -
Losses in a Induction Motor – Power Stages in Asynchronous Motor
Losses, Power Stages and Efficiency of Induction Motor An induction motor (also known as Asynchronous Motor) is widely used in industries to convert electrical power into mechanical power. Therefore, the…
Read More » -
Torque-Slip and Torque-Speed Characteristics of Induction Motor
Torque-speed & Torque-slip Characteristics of an Induction Motor Torque-slip Characteristics Torque-slip characteristics give the relation between torque and slip. The torque-slip characteristics show how the torque changes with a change…
Read More » -
Torque Equation of Induction Motor
Starting Torque, Full Load Torque, Torque at Synchronous Speed & Condition for Maximum Torque Equations of an Induction Motor An induction motor is widely used in industries as it produces…
Read More » -
Equivalent Circuit of Induction Motor
What is the Equivalent Circuit of Induction Motor? An induction motor works on the principle of electromagnetic induction. The working of an induction motor is similar to the transformer. Also,…
Read More » -
What is Motor Generator Set and How Does it Work?
M-G Set – Construction, Working, Advantages, Disadvantages and Applications What is a Motor Generator Set? Motor Generator set is a device used to convert electrical power to another form of…
Read More » -
How to Run a Three-Phase Induction Motor on a Single-Phase Power Supply?
Running a 3-Φ Induction Motor on a 1-Phase Supply – 3 Methods According to the type of AC power supply, induction motors are classified into two types; three-phase induction motor…
Read More » -
What happens if You Connect a 3-Φ Induction Motor to 1-Phase Supply?
What will happen to the 3-Φ (400V) Induction Motor If Connected to 1-Phase (230V) Supply? As the name suggests, a 3-phase induction motor must be connected to the three phases…
Read More » -
What happens to the 3-Phase Motor When 2 Out of 3 Phases are Lost?
What will happen to the 3-Φ Induction Motor Incase of Failure of 2 of the 3-Phases? When a linear or balanced load is connected to the 3-Φ supply system, the…
Read More »