555 Timer
-
Electronics Engineering Project
Basic Voltage Doubler Circuit Diagram using 555 Timer IC
How to Make a Basic Voltage Doubler Circuit? As the name of the article suggests, today this article is to help design a circuit which at its output gives a…
Read More » -
Electronics Engineering Project
LED Roulette Circuit Diagram using 555 Timer & 4017 Counter
Flashing LED Roulette Circuit Diagram using 555 Timer & 4017 ICs There is a casino game and a French word accompanying it called “Roulette”. This circuit resembles the functioning of…
Read More » -
Electronics Engineering Project
24V Flasher Circuit
24V Flasher Circuit Diagram using 555 Timer Industrial level control devices like PLC, HMI, etc. have an operating voltage of 12V or 24V. The loads (LED indicator) and sensors, that…
Read More » -
Basic Electronics
1 Minute, 5 Minute, 10 Minute and 15 Minute Timer Circuit Diagram
1 to 15 Minute Timer Circuit Diagram, Working and Applications In the era of technologies, everyone is taking the help of machines to simplify their life. Timer circuits ease your…
Read More » -
Electronics Engineering Project
Rain Alarm Circuit – Snow, Water and Rain Detector Project
Rain Alarm Circuit – Water, Rain and Snow Defector using Rain Sensor and 555 Timer IC In a world full of automation, everyone wants to stay smart and productive. And,…
Read More » -
Digital Electronics
555 Timer IC- Types, Construction, Working & Application – Circuit & Pinout
555 Timer IC – Mode of Operation – Schematic, Internal, Block Diagram & Applications Digital Timers Timers are those circuits, which provide periodic signals to a digital system which change…
Read More » -
Electrical Design
PCB Designing: How To Design a PCB – Example Circuit
PCB Designing: How To Design a PCB? – Example PCB Design of an LED Flasher Circuit What is a PCB “Printed Circuit Board” ? PCB stands for “Printed circuit board”.…
Read More » -
Electronics Engineering Project
Clap Switch Circuit Using IC 555 Timer & Without Timer
Clap Switch Circuit Electronic Project Using 555 Timer & BC-547 Transistors Introduction to Clap Switch Circuit Clap Switch is a basic electronics mini-project, made with the help of the basic…
Read More » -
Electronics Engineering Project
Traffic Light Control Electronic Project using IC 4017 & 555 Timer
Traffic Light Control Circuit – Simple Electronic Project Introduction Traffic Lights are used to control vehicular traffic on the road and publics streets. In the modern era, where everyone owns…
Read More » -
EE Calculators
IC 555 Timer Calculator with Formulas and Equations
555 Timer Calculator with Formulas and Equations Formulas and Equations for 555 Timer IC Calculator Frequency (f) = 1/ [ ln(2) x C x (R1 + 2R2) ] Frequency (f) = 1.44 /…
Read More »







