Apps - SoftwareCircuit AnalysisEE Calculators

Inductive Reactance Calculator

Inductive Reactance from Inductance Calculator

Note: Formulas and equations for this calculator is given below (right after calculator).

Enter the values of Frequency & Inductance and click on Calculate. Result will display the calculated value of Inductive Reactance.

Inductive Reactance Calculator
Enter values:
Frequency ( f ): Hz
Inductance (L): mH
            
Inductive Reactance XL: Ohms (Ω)

Formula & Equations for Inductive Reactance Calculator

In AC Circuits (Capacitive or inductive Load) Resistance = Impedance i.e., Z = R

Z = √(R2 + XL2)… In case of Inductive Load

Z = √(R2 + XC2)…In case of Capacitive Load

Z = √(R2 + (XL– XC)2…In case of both inductive and capacitive Loads.

Where;

  • X= Inductive reactance
  • X= 2πfL…Where L = Inductance in Henry

And;

XC = Capacitive reactance

XC = 1/2πfC… Where C = Capacitance in Farads

And

Reactance =  Inductive reactance – Capacitive reactance 

i.e.

X = XL– XC

Related Calculators:

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button