Why is the Neutral Prong or Slot Wider on a Plug or Outlet?
Why is the Neutral Prong and Slot Longer than the Hot Prong and Slot on a Plug and Outlet or Receptacle?
Although the electrical power supply and distribution system in the United States is more complex than those in many other parts of the world, it is also among the safest. For example, the U.S. has taken protection of both people and equipment very seriously through the unique design and application of 120V/240V three-prong plugs, receptacles, and outlets commonly used for household appliances.
In North America, the NEMA (National Electrical Manufacturers Association) and NEC (National Electrical Code) define the plug and outlet configurations.
In a standard outlet, the narrow slot represents the hot connection, the wide slot is for neutral, and the round slot is for ground. Similarly, in a three-prong plug, the narrow blade is hot, the wider blade is neutral, and the round blade is ground.
Let’s see why is the neutral prong on a plug and the corresponding slot on an outlet or receptacle wider than the narrow hot prong or slot?
Longer and Wider Prongs and Slots in Plugs and Outlets/Receptacles
Wider and longer prongs and slots on plugs and outlets are used as a safety measure. The wider neutral prong/slot ensures that the plug can only be inserted in one orientation. Due to the special design, the plug is inserted correctly into corresponding outlet, with the wider prong connecting to the neutral wire and the narrower prong connecting to the hot wire.
This polarization guarantees that the hot (live) and neutral wires always connect to the correct terminals in an appliance. This way, polarity in plugs and outlets ensures proper safety against electric shock, fire hazards and damage to the appliance. In short, polarized plugs and outlets are more safer and recommended to use than the non-polarized plugs and outlets.
- Related Post: Why Do Prongs in Electrical Plugs Have Holes in Them?
Why it Matters?
The hot side carries the voltage (typically 120V or 240V in North America), while the neutral side completes the circuit at ground potential (0V). By making the neutral slot wider, it prevents incorrect insertion, reducing the risk of shock or fire.
The neutral wire is electrically bonded to ground at the main service panel. If someone touches the neutral prong, the risk of electric shock is much lower compared to the hot prong, which carries 120 or 240V volts. By making the neutral prong larger, the plug can only be inserted in one way, ensuring the correct polarity and proper operation of the circuit.
Many appliances, especially older ones or those with metal casings, rely on proper polarity to ensure that the switch or fuse cuts off the hot wire. If the polarity is reversed, the appliance may still appear “OFF”, but internal parts could remain electrically live, posing a shock hazard.
Imagine a toaster with a two-prong plug. The neutral prong is larger to ensure it’s connected to the neutral slot in the outlet, and the smaller hot prong connects to the hot slot. If you accidentally try to insert the plug the wrong way into the outlet, it won’t fit due to the difference in the sizes of the prongs and slots. This ensures a proper and safe connection i.e. hot to hot, neutral to neutral, and ground to ground. This design helps prevent accidental shocks by ensuring that the correct wiring is established between plug and the outlet.
Additionally, In grounded plugs (with a third ground prong), the orientation is fixed by both the ground and the wide neutral prong. Keeping neutral as the wide prong maintains consistent plug design across 2-prong and 3-prong plugs. This is why only one prong or slot is wider and the the other one for Hot is short or narrow.
In the US, the NEC requires the NEMA designed plug and outlet configuration to ensure standardized and safe electrical systems and installations.
Related Posts:
- Why is Earth Pin Thicker and Longer in a 3-Pin Plug?
- Why are there Grooved Slots in the Pins of Two Pin Plugs?
- What are the Tiny Cylinder in Power Cords & Cable?
- Why are US Homes Wired Using Solid Wire rather than Stranded Wire?
- Which Bulb Glows Brighter When Connected in Series and Parallel & Why?
- Which One Kills – Current or Voltage and Why? Amps vs Volts
- Which One is More Dangerous And Why? AC or DC ?
- Which One is More Dangerous? 120V or 230V and Why?
Resources & Tutorials:
- Difference Between Socket, Outlet and Receptacle?
- How to Find the Voltage Ampere Rating of Plugs & Outlet & Receptacle?
- How to Wire and Install an Electrical Outlet Receptacle?
- 25 Different Types of Light Switches
- How to Wire a UK 3-Pin Plug? Wiring a BS1363 Plug
- How to Wire a UK 3-Pin Socket Outlet? Wiring a BS1363 Socket
- How to Wire a Twin 3-Pin Socket Outlet? Wiring 2-Gang Socket








The neutral prong or slot is wider on a plug or outlet as a safety measure to ensure correct polarization. The wider neutral blade only fits into the wider neutral slot, preventing the plug from being inserted incorrectly. This design helps to ensure that the hot wire is connected to the correct side of the appliance, reducing the risk of electrical shock.
There used to be products such as Radios and others that did not have an isolation transformer in them and this helped make sure the chassis was not connected to Line (Black) since there was no third ground pin on the plug
History lesson (event sequence is correct, dates are my best guess)
In the 1940s plugs/receptacles had both terminals with the same size… which means that the plug could be plugged in either way.
In the 1960s they started making “polarized” plugs, still only two terminals but the neutral was longer than the hot terminals. New plugs could be plugged in one orientation. The design allowed the older legacy plugs to be used.
In the 1970s they kept the same two terminal layout the same and added the round hole at the bottom. Plugs were molded with the ground/round hole at the bottom
In 2000 someone got the bright idea of turning the receptacles upside down making the previously molded plugs awkward to plug in. With this configuration all of the legacy plugs will still work.
The hot side of a this style receptacle is NOT smaller to ensure proper polarization. This slot was intentionally smaller because it is the “HOT HOLE” and by being smaller makes it proportionally less likely for common metallic objects to be jabbed in by a curious someone (child). This factor is what created the standardization of the “big slot (silver screw), little slot (gold screw)” on this style of receptacle. The safety of polarization was then maintained as a result of making these different sizes that only go in one way.
On a construction site with twist-lock connectors this is different because the curious someones are less likely to be on site poking into the slot so the slots are opposite with the larger slot used as the HOT to minimize DROP across the connection.
Twist-lock: (BIG SLOT -black wire- gold screw)
(SMALL SLOT-white wire-silver screw)