How to Wire 120V Water Heater Thermostat – Non-Simultaneous?

Single Phase 120V Non-Continues Dual Element Water Heater Thermostat Wiring

In the electric water heaters and thermostat wiring and installation series, we will be showing that how to wire and install a non-simultaneous (non-continuous) dual element water heater and thermostat for 120V AC single phase (US) and 230V AC single phase (EU/UK).

Non-Simultaneous or Non-Continuous Operation of Water Heater

Non continuous or non-simultaneous heating elements are dependent on each other i.e. both elements are not “ON” at the same time. In other words, the upper heating element will turn “ON” and heat the top of the water tank first. The redundant or lower element will turn on when cold water enters the tank. This is an automatic process due to the thermostat wiring connection where the lower thermostat and element is controlled by the upper thermostat which automatically turns on the lower element when needed..

This way, both elements won’t operate at the same time. In very simple words, either the upper or lower heating element is “ON” or both are “OFF”. Keep in mind the same thermostats can be wired for simultaneous or continuous operation where both elements are operational at the same time in case of more hot water consumption. Don’t worry, we will cover these kinds of operations in our next posts.

120V AC Single Phase Dual Element Water Heater Thermostat Wiring

In non-simultaneous water heater thermostat wiring, the Phase or Hot “L” is connected to the left terminal L1 of the upper thermostat and Neutral “N” is connected to the right terminal L3. Two wires are outgoing from L4 as neutral to the upper and lower heater elements. The upper heating element is connected through T2 and L4.

The lower thermostat is connected through T4 of the upper thermostat which is wired to the terminal “1” of the lower thermostat. The second terminal “2” is connected to the lower heating element.

Since there are two heating elements each rated about 1900 watts, the total wattage rating of this heater is 3800 watts. We will be using the breaker and switch sizes for half rating of the total wattage i.e. 1900 watts as only one element is operating at a time.

Click image to enlarge

120V AC Single Phase Dual Element Water Heater Thermostat Wiring

Now in case if 120V AC, a 20A circuit breaker and single way switch is suitable for both wires having 12 gauge size. How? Let’s see as follow.

  • Total wattage: 3800 / 2 = 1900 Watts.
  • Load Current = 1900 / 120V = 15.83A.

Breaker Size should be 1.25 (125%) of the load current:

15.83 x 1.25 = 19.79A

Another way, the safe limit of circuit breaker is 80% (0.8), this way 20A x 0.8 = 16 Amp which is safe for load current.

This way, a 20A circuit breaker for over current protection is suitable in case of dual element non-continuous water heater circuit for 120V AC.

230V AC Single Phase Dual Element Water Heater Thermostat Wiring

The following wiring diagram shows the same connection as above despite the breaker and switch size rating according to the NEC and IEC. The wiring connection and working is the same as above for 120V configuration.

Click image to enlarge

120V & 230V AC Single Phase Dual Element Water Heater Thermostat Wiring

Non-Simultaneous Thermostat Operation

In this case, the power enters through L1 and L3 (upper thermostat) which operates the upper element. Once the temperature in the upper portion of the water tank rises to the desired (according to the rating i.e. 150° to 180°F) , the bimetallic strip in the upper thermostat releases and separates the T2 from T1 and connects T1 to the T4 terminal. This way, the upper element is turned off and power continues to the lower element through L4 and T4.

This process is shown in the following fig. fig (a) shows the upper element operation while fig (b) shows the lower thermostat and element operation when they are active.

Water Heater Thermostat Wiring and Working

Note: In the above diagram, the Red color illustrates the Line or Phase wire and Black color shows the Neutral Wire in the above figures. You may follow your regional wiring color codes i.e. IEC or NEC.

Related Posts:

Warning:

  • Disconnect the power before replacing, repairing, troubleshooting, maintenance and installation electrical appliances and equipment.
  • Use the suitable voltage and ampere rating of switch with appropriate wire size and proper size of breaker according to the load rating.
  • Failure to do so can result in electrical shock, serious injury, fire or even death.
  • Please follow the manual instruction, local area codes or contact a licensed electrician for proper installation.
  • The author will not be liable for any losses, injuries, or damages from the display or use of this information or if you try any circuit in the wrong format. So please! Be careful because it’s all about electricity and electricity is too dangerous.

Related Wiring Installation Tutorials

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.

3 Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button