Circuit Analysis
-
Synchronous, Stepper and AC Motors Formulas and Equations
AC Machine Formulas & Equations for Stepper and Synchronous Motors Following are the useful equations and AC motors formulas while designing and analyzing synchronous motors, stepper motors and other related…
Read More » -
Power, Voltage and EMF Equation of a DC Motor – Formulas
DC Motors Formulas and Back EMF Equation EMF Equation of a DC Motor The basic DC motor’s E.M.F equation is given below. Eb = PΦNZ / 60A Where; P is…
Read More » -
Induction Motor & Linear Induction Motors Formulas & Equations
Formulas and Equations for Linear and Induction Motors The following equations and formulas related to linear and induction motors can be used to calculate the basic parameters while analyzing and…
Read More » -
Transformer Formulas and Equations
Electrical Transformer Formulas & Equations The following parameters can be calculated by using the basic electrical transformer formulas, equation and functions while designing and analyzing transformers related circuits and networks.…
Read More » -
Power Formulas in DC and AC Single-Phase & Three-Phase Circuits
Electric Power Formulas & Equations in DC and AC 1-Φ & 3-Φ Circuits Back to basic, below are the simple Electric Power formulas for Single Phase AC Circuit, Three Phase…
Read More » -
Basic Electrical Engineering Formulas and Equations
Basic Voltage, Current, Power and Resistance Formulas in AC and DC Circuits Following are the electrical engineering formulas and equations for the basic quantities i.e. current, voltage, power, resistance and…
Read More » -
Generator Protection – Types of Faults & Protection Devices
Types of Generator Faults and Protection Devices Common Generator Faults Generator faults are usually classified into internal and external faults; internal faults are due to problems within the generator components…
Read More » -
Star to Delta & Delta to Star Conversion. Y-Δ Transformation
Star to Delta and Delta to Star Transformation – Y-Δ Conversion In an electrical network, the impedance can be connected in various configurations. The most common of these configurations are…
Read More » -
Difference Between Series and Parallel Circuit – Comparison
Key Differences between Series and Parallel Circuits In electrical and electronics engineering it is very important to know the differences between series and parallel circuits. They are the two most…
Read More » -
Difference between AC and DC (Current & Voltage)
Difference Between AC (Alternating Current) & DC (Direct Current) The Alternating Current (AC) and Direct Current (DC) are the two types of electric currents that coexists in our daily life.…
Read More »