Protection
-
Electrical Grounding and Earthing – Methods, Types and Installation
Electrical Earthing & Grounding – Components, Methods & Types of Earthing – Electrical Grounding Installation According to NEC and IEC What is Electrical Grounding or Earthing? Earthing, also known as…
Read More » -
High Inrush Current in Capacitor Switching and Ways to Prevent It.
How to Prevent the high Inrush Current in Capacitor Switching? Introduction to High Inrush Current in Capacitor Switching Applications of capacitance switching are not only restricted to capacitive currents but…
Read More » -
What is Nuclear Power and How a Nuclear Power Plant Works?
How Does a Nuclear Power Plant Work? What is Nuclear Energy? Nuclear energy is becoming well developed as a source of energy. Compared to other sources of energy like solar…
Read More » -
Fault Current Limiter and Their Types
Fault Current Limiter (FCL) & Current Limiting Reactors (CLR) Introduction to Fault Current Limiter: These days due to increase in demand of energy, solid development in generation and transmission is…
Read More » -
Why are Electrical Cables and Wires insulated?
What is Purpose of Insulated Covers around Wires and Conductors? Insulator, Insulation & Insulation Materials? An insulator is a material or substance that does not readily conduct heat or electricity.…
Read More » -
GFCI: Ground Fault Circuit Interrupter. Types, Working & Applications
What is a GFCI (Ground Fault Circuit Interrupter) and How Does it Work? At home or outside, we cannot do without electricity and electrical devices. These are indispensable necessities in…
Read More » -
HRC Fuse (High Rupturing Capacity Fuse) and its Types
HRC Fuse (High Rupturing Capacity Fuse) and its Types What is High Rupturing Capacity (HRC) Fuse? A High Rupturing Capacity (HRC) Fuse is a type of fuse used in electrical…
Read More » -
Air Circuit Breaker (ACB) – Construction, Operation, Types and Uses
ACB (Air Circuit Breaker) – Construction, Operation, Types, Advantages and Applications What is a Circuit Breaker? A circuit breaker is a device, which is capable to: Break a circuit automatically…
Read More » -
Fuse and Types of Fuses – Construction, Operation & Applications
Different Types of Fuses – Constriction, Working & Characteristics What is a Fuse? A fuse is an electrical / electronic or mechanical safety device designed to protect circuits from overcurrent…
Read More » -
Factors of Contactor’s Contact Design
Factors of Contactor’s Contact Design The Following factors consider while designing the Contactor’s contacts Current carrying Capacity The ability of current carrying capacity of contacts takes into account while designing contactor’s…
Read More »