Zener Diode & Zener Voltage Regulator Calculator

Zener Diode & Zener Voltage Regulator Calculator

Zener Diode & Zener Voltage Regulator Calculator

Formulas and Equations for Zener Diode & Zener Voltage Regulator Calculator

Series Current

IS= VIN – VZ / RS….. (Ohm’s Law Again)

Load Voltage

VL = VZ

Change in Load Voltage

∆VL = IZ x RZ

Output (Regulated) Voltage

VOUT= VIN – IR = VIN – (IZ + IL) / RS = (VIN – IS) / RS

Load Current

IL = VL / RL

Zener Current

IZ = IS – IL

Output ripple

VR (OUT) ≈ VR (IN) x (RZ/RS)

Maximum Series resistance

RS (MAX) = RL (MIN) x [(VIN (MIN) / VZ) -1]

Maximum Series resistance

RS (MAX) = RL (MIN) x [(VIN (MIN) – VZ) / IL(MAX)]

Or Series Resistance

RS = (VL – Vout) / (IZ + IL) = (VL – Vout) / (IS)

Value of Resistor

R = [(VIN (MIN)– VOUT) / (IL + 10)]

Power of Resistor

RP = (VIN (Max) – Vout) 2­­ / R

Power of Zener Diode

ZP = (VIN (MIN) – VOUT) / R) x VOUT

Enter value and click on calculate. Result will be displayed.

Enter Values:
Max Input Voltage (VIN (Max)): Volts
Min Input Voltage (VIN (Min)): Volts
Output Voltage (VOut): Volts
Load Current (IL): mAmp
      
Zener: Volts Zener Power: Watts
Resistance: (Ω) Ohms Resistance Power: Watts

Related Electrical Calculators:

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.

5 Comments

  1. To calculate Vout , we need Rs
    VOUT= Vin – Ir = Vin – (Iz + IL) / Rs = (Vin – Is) / Rs

    and then to calculate Rs We need V out again

    RS = (VL – Vout) / (IZ + IL) = (VL – Vout) / (IS)