Why the Voltage in a Short Circuit is Zero and Current is High

Why the Reactance and Voltage under Fault Condition is Low and Current is High

Theoretically and ideally, the Voltage and Reactance of a system (under fault condition such as short circuit) becomes low to zero and fault current may rise to the highest dangerous value.

We know that the power in watts is constant from supply source and under fault conditions in ac circuits such as short circuit there is no load and impedance “Z”, reactance i.e. inductive reactance and capacitive reactance which is equal to the overall resistance of ac circuits.

Why the Reactance and Voltage under Fault Condition is Low and Current is High

When short circuit occurs, there will be no resistance or reactance and current will be too much high. In this case, when power is constant and current increases, voltage will be decreased.

To understand this basic point, let consider the following example.

Suppose, (In normal condition)

Power = P = 1000 Watts

Voltage = V = 110 Volts

Current = I = 9.09 Amp.

But in Short circuit condition, (When current is too high)

Then,

P = 1000 Watts

I = 1000 A

V = P ÷ I

1000 Watts ÷ 1000A = 1 V.

To know why the system voltage under fault condition is too low, according to the ohm’s law:

V = I × R

As in case of short circuit, there will be no load i.e. resistance and reactances, so if we put resistance as zero in ohm’s law, the voltage will be too low due to high value of current flowing through the conductor as the circuit resistance is almost zero.

So we can say that, in case of short circuit and fault conditions, Inductive reactance is zero, current increases to the higher value and voltage decreases as power is constant from the power house.

Good to know:

  • The system reactances ( Inductive reactance and capacitive reactance) is almost zero under fault conditions such as short circuit.
  • In case of short circuit, the system resistance is ideally zero.
  • The value of voltage between two points is theoretically “0” when short circuit occurs between phase and neutral.
  • Current rises to the dangerous value in case of short circuit which leads to damage the connected appliances and installation.
  • Proper protection, such as insulation and protective circuits like fuses and circuit breakers, is advised to prevent short circuits and dangerous sparks, which can lead to damage to the overall system or even hazardous fires.

Related Question / Answers

➡️ READ FULL ARTICLE 📖

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.