Formula and Equations For Capacitor and Capacitance

Capacitor and Capacitance Formulas and Equations

The following formulas and equations can be used to calculate the capacitance and related quantities of different shapes of capacitors as follow.

Capacitor and Capacitance Formulas and Equations

Capacitance of Capacitor:

The capacitance is the amount of charge stored in a capacitor per volt of potential between its plates. Capacitance can be calculated when charge Q & voltage V of the capacitor are known:

C = Q/V

Charge Stored in a Capacitor:

If capacitance C and voltage V is known then the charge Q can be calculated by:

Q = C V

Voltage of the Capacitor:

And you can calculate the voltage of the capacitor if the other two quantities (Q & C) are known:

V = Q/C

Where

Reactance of the Capacitor:

Reactance is the opposition of capacitor to Alternating current AC which depends on its frequency and is measured in Ohm like resistance. Capacitive reactance is calculated using:

capacitive reactance

Where

Quality Factor of Capacitor:

Q factor or Quality factor is the efficiency of the capacitor in terms of energy losses & it is given by:

QF = XC/ESR

Where

Dissipation Factor of Capacitor:

D factor or dissipation factor is the inverse of the Quality factor, it shows the power dissipation inside the capacitor & is given by:

DF = tan δ = ESR/XC

Where

Related Posts:

Energy Stored in a Capacitor:

The Energy E stored in a capacitor is given by:

E = ½ CV2

Where

Average Power of Capacitor

The Average power of the capacitor is given by:

Pav = CV2 / 2t

where

Capacitor Voltage During Charge / Discharge:

When a capacitor is being charged through a resistor R, it takes upto 5 time constant or 5T to reach upto its full charge. The voltage at any specific time can by found using these charging and discharging formulas below:

During Charging:

The voltage of capacitor at any time during charging is given by:

Capacitor charging

During Discharging:

The voltage of capacitor at any time during discharging is given by:

Capacitor discharging

Where

Related Posts:

Capacitance Formulas

The capacitance between two conducting plates with a dielectric between then can be calculated by:Capacitance

Wheredielectric constant

Capacitance of a Plate Capacitor Formula

Capacitance of a Plate Capacitor

Where:

Self Capacitance of a Coil (Medhurst Formula)

C2 ≈ (0.256479 h2 + 1.57292 r2) pF

Where:

Self Capacitance of a Sphere Formula

C2b ≈ 4πεor

Where:

Self Capacitance of a Toroid Inductor Formula

Self Capacitance of a Toroid InductorWhere:

Ohm’s Law for Capacitor:

Q = CV

By differentiating the equation, we get:Ohm’s Law for capacitor

where

Related Formulas and Equations Posts:

↑