Why Does the High-Wattage Bulb Glow Dimmer in a Series Circuit?
Why Does a High-Wattage Bulb Glow Dimly When Connected in a Series Circuit, While a Low-Voltage Bulb Glows Brightly in the Same Circuit?
Three light bulbs are connected in a series circuit which is powered by the source voltage of 230V AC supply.
- The rating of the first bulb is 10 Watts
- The rating of the middle bulb is 50 Watts.
- The rating of the last bulb is 10 watts.
Now, why is the high-wattage (50 watts) bulb connected in the middle of a series circuit glowing dimly compared to the first and last bulbs, each rated at 10 watts, which are glowing brightly?
Related Posts:
- Why Does the High-Wattage Bulb Glow Brighter in a Parallel Circuit?
- Which Bulb Glows Brighter When Connected in Series and Parallel and Why?
The main reason for this scenario is the basic principle that a bulb dissipating more power will glow brighter, whether it is connected in a series or parallel circuit. In other words, a bulb with high resistance will glow brighter, while a bulb with low resistance will glow dimmer. This is because the bulb with lower resistance dissipates less power, where the brightness of the bulb is directly proportional to the light brightness.
Now, we will find the current flowing through and the resistance of each bulb because the brightness of the light bulb depends on the current, voltage, and its resistance. This is because the brightness of the light depends on the power dissipated by the light bulb, not the rating of the light bulb.
As it is a series circuit, we know that in a series circuit, the current is the same at each point while the voltage and resistances are additive, i.e.
- Current in series circuit: IT = I1 = I2 = I3 …In
- Voltage in series circuit: VT = V1 + V2 + V3 …+ Vn
- Resistance in series circuit: RT = R1 + R2 + R3 …+ Rn
- Related Post: Why is Earth Pin Thicker and Longer in a 3-Pin Plug?
Determining the Total Resistance of the Lights
As the same current flows through all three bulbs connected in series, we can use Ohm’s law to determine the resistance of each bulb, which will allow us to calculate the power dissipation by the light bulb (P = V×I). Let’s find the resistance of each bulb using Ohm’s Law.
Resistance of 10W Bulb (Each)
- ➺ R10W = V2 / P10
- ➺ R10W = 2302 / 10W
- ➺ R10W = 5,290 Ω
This is the resistance value for both the first and last bulbs, which are rated at 10W. Let’s find the resistance of the bulb connected in the middle, which has a high wattage rating, e.g., 50W.
Resistance of 50W bulb (Connected in the Middle)
- ➺ R50W = V2 / P50
- ➺ R50W = 2302 / 50W
- ➺ R50W = 1,058 Ω
We see that the resistance of the high-wattage (50W) rated bulb connected in the middle of the series circuit is lower than the resistance of the low-wattage bulbs (10W).
Calculating the Current Flowing in the Circuit
Now, let’s determine the total current flowing in the series circuit using Ohm’s law.
- ➺ I = V ÷ RTotal
- ➺ I = V ÷ (R10W + R50W + R10W)
- ➺ I = 230V ÷ (5,290Ω + 1,058Ω + 5,290Ω)
- ➺ I = 19.76 mA.
Calculating the Power Dissipation of the Bulbs
Hence, the power dissipated by the lower wattage bulb (either the first one or the last one, each having a 5-watt rating) can be calculated using the power dissipation formula (P = I2R).
Power Dissipated by 10W Bulb (Each)
- ➺ P10W = I2R10W
- ➺ P10W = (19.76mA)2 x 5,290Ω
- ➺ P10W = 2 Watts.
Power Dissipated by 50W Bulb
Similarly, the power dissipated by the 50W bulb connected in the middle of the series circuit
- ➺ P50W = I2R50W
- ➺ P50W = (19.76mA)2 x 1,058Ω
- ➺ P50W = 0.41 Watts.
Now, we see that the 50W bulb connected in the middle of the series circuit is consuming less power (0.41 Watts) compared to the first and last bulbs (each rated at 10W), which consume 2 Watts each. That’s why the middle bulb connected in the series circuit, even though it has a high-wattage rating, is glowing very dimly compared to the other low-wattage bulbs, which glow brighter.
Related Posts:
- What is the Objection to having Light Bulbs & Lamps Connected in Series?
- Advantages of Parallel Lighting Circuit over a Series Circuit
Alternatively, you can calculate the total resistance (by adding the resistance of each bulb), so the equivalent resistance will be 11,638 ohms. Then, you can calculate the voltage drop across each bulb by multiplying the current flowing through the bulb by the related resistance of that bulb. Use a calculator for these calculations.
- Total Resistance = RT = 11,638 Ohms
- Voltage drop across 5-W bulb (each) = 104.55 V
- Voltage drop across 50-W bulb = 20.9 V
- Total Voltage drop = VDrop = V1 + V2 + V3 = 230V
- Total Current = IT = 19.76 mA
- Related Post: Why is the Grounding Wire Bare and Not Insulated?
Based on the above calculations, we now understand why the low-wattage rated bulbs (10W) glow brighter and the high-wattage rated bulb glows dimmer when connected in a series circuit. This is because the same current flows through all bulbs, while the wattage and resistance values are different. The low-wattage bulbs have high resistance and dissipate more power hence, they glow brighter. While the high-wattage bulb has low resistance and dissipates less power, hence, it glows dimly.
Related Posts:
- What are the Colored Aerial Marker Balls on Power Lines For?
- Will I Get an Electric Shock If I Touch the Ground Wire?
- Can the Neutral Wire Cause Electric Shock? Different Cases
- Will a Man Get an Electric Shock If He Hangs on a Live Wire?
- What are the Tiny Cylinders in Power Cords and Cables?
- Introduction to Series, Parallel and Series-Parallel Connections
- Series, Parallel and Series-Parallel Connection of Batteries
- Difference Between Series and Parallel Circuit – Comparison
- How To Wire Switches In Series?
- How To Wire Switches in Parallel?
- How To wire Lamps in Series?
- How To Wire Lamps in Parallel?









its confusing to me that the bulb with high resistance glows brighter; because high resistance causes more voltage drop in a circuit ……what am I getting wrong ?
Since this is a series circuit, the same amount of current flows through all the light bulbs. The 50W bulb has a lower resistance (1,058 Ohms) compared to the other bulbs, so it dissipates less power (0.41 Watts). That’s why it glows dimmer when connected in series.
The situation is the opposite when the same bulbs are connected in a parallel circuit.
If you’re interested, here is a case study with solved examples: