Power, Voltage and EMF Equation of a DC Motor – Formulas

DC Motors Formulas and Back EMF Equation

EMF Equation of a DC Motor

The basic DC motor’s E.M.F equation is given below.

Eb = PΦNZ  / 60A

Where;

  • P is the number of poles
  • Ф is the Flux per pole
  • N is the Speed of motor in (RPM)
  • Z is the Number of conductors
  • A is the Number of parallel paths

In a final designed motor, the number of poles “P”, conductors “Z” and parallel paths “A” are fixed, therefore, the following quantities and parameters remains constant.

Eb ∝ ΦN

Eb = kΦN        …..        (1)

Where k is the Proportionality constant

The back EMF of DC motor equation can also be defined as 

Eb = V – IaRa        …..        (2)

Where;

Now compare both equations of (1) and (2);

kΦN = V – IaRa

k = N = V – IaRa / kΦ

The above relation shows that the speed of a DC motor can be controlled through change in voltage, flux and armature resistance.

Related Posts:

Power, Voltage and EMF Equation of a DC Motor -Formulas and Equations for DC Motors

Voltage Equation of a DC Motor

Input Voltage provided to the motor armature performs the following two tasks:

i.e.

V = Eb + IaRa        …..        (1)

Where

The above relation is known as “Voltage Equation of the DC Motor”.

Power Equation of a DC Motor

Multiplying both sides of Voltage Equation (1) by Ia , we get the power equation of a DC motor as follow.

VIa= EbIa + Ia2 Ra        …..        (2)

Where,

Related Posts:

Shunt Motor:

Voltage Equation of Shunt Motor:

V = Eb + Ia x Ra

Where

The Shunt Field Current:

I­sh ­= V / Rsh

Where

Induced Back EMF:

The armature induced voltage Eb is proportional to the speed & it is given by:

Eb = kfΦω

Where

Maximum Power Condition:

The output mechanical power is of shunt dc motor is maximum when the back e.m.f. produced is equal to the half of its terminal voltage i.e.

Eb = V/2

Torque & Speed:

Torque & Speed of DC shunt Motor
And
Machine constant
Where

Related Posts:

Speed Regulation:

It is a term expressed in percentage that shows the change of motor speed when the load is changed.

Speed Regulation of DC Shunt Motor
Where

Input & Output Power:

Pin = VIa

Pout = T ω

Where

Related Posts:

Series Motor:

Voltage Equation Of Series Motor:

V = Ea + Ia Ra + IaRse

V = Ea + Ia(Ra+Rse)

Where

Armature Induced Voltage & Torque:

The armature induced voltage Ea is proportional to the speed and armature current whereas the torque Ta of series motor is directly proportional to the square of armature current & it is given by:

Ea = kfΦωIa

Ta = kf Φ Ia2

Where

Speed of Series Motor:

Speed of DC series motor

Input & Output Power

The input power of a series motor is given by:

Pin = VIa

The output power is given by

Pout = ωT

Related Posts:

Efficiency Of DC Motor:

The different motor efficiencies can be found by the following formulas and equations

Electrical Efficiency:

ηe =  Converted power in armature / Input electrical Power
Electrical efficiency of DC motor

Mechanical Efficiency:

ηm = Converted power in armature / output mechanical power
Mechanical Efficiency of DC Motor

Overall Efficiency:

η = Output mechanical Power / Input electrical Power
η = (Input Power – Total losses) / Input Power
Overall Efficiency of DC Motor
Where

Related Formulas and Equations Posts:

↑