Basic ElectronicsCommunicationDigital ElectronicsElectronicsSignals

MAX232: Construction, Operation, Types and Application

MAX232: Construction, Operation, Types Application and uses in different Electronics Circuits.

What is MAX232?

Max232 is designed by Maxim Integrated Products. This IC is widely used in RS232 Communication systems in which the conversion of voltage level is required to make TTL devices to be compatible with PC serial port and vice versa.

This chip contains charge pumps which pumps the voltage to the Desired Level. It can be powered by a single +5 volt power supply and its output can reach +_7.5 volts. MAX232 comes in 16 Pin Dip and many other packages and it contains Dual Drivers.

It can be used as a hardware layer converter for 2 systems to communicate simultaneously. Max232 is one of the versatile IC to use in most of the signal voltage level conversion problems.MAX232 IC, MAX-232, MAX 232

Construction of MAX232:

Mostly MAX232 used in 16-pin DIP package. it consist of 3 major blocks .It can only be powered by 5 volts to make it power supply compatible with most of the embedded systems.

First block is the voltage doubler in this ic switched capacitor techniques is used to make the voltage double. Once the voltage is doubled second block will converts that voltage to +10 and -10. The third block consists of 2 transmitters and 2 receivers which actually convert the voltage levels.MAX232 IC Construction Circuit

External components:

Max232 requires minimum 4 external capacitor. Their Value can range from 1μf to 10μf and 16 volts or more rating. There are many different versions of this versatile ic available each of them Require different capacitor value for proper working.Required Capacitors Value for MAX232 external components for MAX232 IC

Application and uses of MAX232:

primarily, MAX232 is used in Serial communication. Problem arises when we have to communicate between TTL logic and CMOS logic based systems.

RS232 is internationally defined standard named as EIA/TIA-232-E and in this standard logic 0 is the voltage between +3 to +15 and logic 1 is defined as the voltage between -3 to -15.In TTL logic 0 is defined is by 0 volt and 1 is defined by 5 volt so in this scenario this is a very handy IC to be incorporated.

Other Applications & Uses

  • Battery Powered RS 232 Systems
  • Interface Translation
  • Low Power Modems
  • RS 232 Networks (Multi-drop)
  • Portable Computing

Related Post: Serial Communication by Arduino

PC Serial PORT communication by using MAX232 IC:

Desktop and some old Laptops have Serial port which comes in DB9 package. In Most of the Circuits designer is concerned about the Tx and Rx pins only so the function of the rest of the pins are not used here mostly.

In the above circuit only one Driver is used and second driver can be used for other purpose. TTL data is available on pin 12 and pin 11 and these pins can be attached to Microcontroller or any system which accept TTL logic.

PC Serial PORT communication by using IC MAX232

GSM Modem Communication:

There are many GSM modems available in the market and most of them are on TTL logic but some of them use RS232 standards and again it becomes a problem to communicate wilt GSM modem by using Micro controller, aurdino or any other TTL platform.MAX232 is used to solve this problem.GSM Modem Communication by MAX 232

Types of MAX232:

  • 1) “MAX232N” where “N” Represent PDIP package Style this package is easy to sold and most widely used.
  • 2) “MAX232D” where “D” indicates the SOIC package which is difficult to sold and required a trained professional to be used correctly.
Common Mistakes:
  • Capacitor voltage rating is less than 16.
  • Interchange Tx and Rx pins on one side of MAX232 at one time.
  • Distorted power supply. Use decoupling capacitor to remove distortion.
  • Check all the connections again.
  • Check the capacitor with capacitance meter.
  • Use Tantalum Capacitor for better performance.

Credit: Electrical Technology, Scott W Harden, MAXIM

Related Posts:

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.

5 Comments

  1. Sir there is a question in my mind, if a circuit disgine for 9v dc and i want to operate it on 220v AC. What should i do. There is one way that i know is, step dowm transformer and rectifier. But if I dont have transformer, but resistors. Kindly tell me resistor velue to step down…. Thanks

  2. Wow, I like your advancements in electrical technology.Intergrated circuits are really awesome. I’m also an electrical engineering student but I don’t have the means to expand my knowledge to higher height.

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button