Basic ElectronicsBoolean Algebra & Logic FamiliesCombinational Digital CircuitsDigital ElectronicsEE SymbolsLogic Gates

Two-Level Logic Implementation – Combinational Logic Implementation

Two-Level Logic Implementation – Implementation of Combinational Circuits

Introduction

Two level logic means that the logic design uses maximum two logic gates between input and output. This does not mean that the whole design will contain only two logic gates but the single path from input to output may contain no more than two logic gates.

For two-level logic implementation, we consider four logic gates i.e. AND Gate, OR Gate, NAND Gate, and NOR Gate. If we use one of these four gates at first level and one at the second level then we get a total of 16 combinations of two-level logic.

Each two-level combination implements different logic functions, There are two main types in these 16 combinations.

  • Degenerate Form
  • Non-Degenerate Form

Degenerate Form

The two-level combination that degenerates into a single logic function as known as degenerate form.

There are 8 degenerate forms in those 16 combinations. Each of these degenerate forms is given below with examples.

AND-AND Combination

This AND-AND gate combination is a degenerate form because the whole function results in an AND function of all the inputs.

In AND-AND combination, the first level gate is AND gate and the second level gate is also AND gate as shown in the schematic given below.

AND-AND combination

It’s Expression

(A & B) & C         =      A & B & C                            (A & B) (C & D)         =        A & B & C & D

The only benefit of this combination is that it can increase the number of inputs for AND gate with less number of inputs but increases the gate delay.

Also read:

OR-OR Combination

OR-OR gate combination gives out Logic Function OR as output. This combination can implement OR function with multiple inputs.

Schematic of OR-OR combination is given below:

( A+ B+ ) + C            =             A + B + C

OR-OR Gate combination

AND-NAND

This Two-level combination of logic gates results in NAND function. So this combination can be used for NAND function with multiple inputs.

Its expression and schematic are given below.

( ( A . B ) C )’              =             ( A . B . C )’

AND-NAND Combination

OR-NOR

OR-NOR combination of gates results in NOR logic function. And this degenerate form can be used for NOR function with multiple inputs.

Its expression and schematic are given below.

( ( A + B ) + C )’          =             ( A + B + C )’

OR-NOR combination

NAND-NOR

When NAND-NOR combine in Two-level logic the resultant function is AND logic .its expression and schematic is given below;

(( A.B )’ + ( C.D )’)’             =                (A.B.C.D)

Its graphical conversion is given below.

Schematic of NAND-NOR combination

Figure (a) contains Schematic of NAND-NOR combination.

NOR gate converted into INVERT-AND gate

In figure (b), NOR gate is converted into its equivalent INVERT-AND gate.

Two-Level Logic Implementation AND gates

In figure (c), the two bubbles on the same line cancel each other because a bubble means inversion and double inversion means no change. So the resulting figure contains only AND gates.

Also read:

NOR-NAND

NOR-NAND combination also results in OR function that’s why it is also a degenerate form. Its Example with schematic is given below;

( ( A + B )’ ( C + D )’)’ =             ( A + B + C + D )

Graphical conversion of NOR-NAND to OR function is given below.

Schematic of NOR-NAND combination

 

Figure (a) contains Schematic of NOR-NAND combination.

NAND gate converted into INVERT-OR gate

In figure (b), NAND gate is converted into its equivalent INVERT-OR gate.

Two-Level Logic Implementation OR gates

In figure (c), the two bubbles on the same line cancel each other because a bubble means inversion and double inversion means no change. So the resulting figure contains only OR gates.

NAND-OR

This combination also results in NAND logic function just like AND-NAND combination.

Its expression and schematic are given below.

( ( A . B )’ + ( A . B )’ )   =             ( A . B . C . D ) ’

Its graphical conversion is given below.

schematic of NAND-OR combination

Figure (a) contains schematic of NAND-OR combination.

INVERT-OR gate

In figure (b), the bubbles from the output of 1st level NAND gate is moved to the input of 2nd level OR gate making it INVERT-OR gate.

AND-NAND combination

In figure (c), the INVERT-OR gate is replaced with NAND gate because they are equivalent. Thus the design becomes AND-NAND combination. 

Also read:

NOR-AND

This combination is same as OR-NOR combination because this combination also results in a NOR function.

Its expression and schematic are given below.

( A + B )’. ( C + D )’     =             ( A + B + C + D )’

Its graphical conversion is given below.

Schematic of NOR-AND Combination

Figure (a) contains schematic of NOR-AND combination.

INVERT-AND gate

In figure (b), the bubbles from the output of 1st level NOR gate is moved to the input of 2nd level AND gate making it INVERT-AND gate.

OR-NOR combination

In figure (c), the INVERT-AND gate is replaced with NOR gate because they are equivalent. Thus the design becomes OR-NOR combination. 

Non-Degenerate Form

Those combinations of Two-level logic, which implements Sum of Product form or Product of sum form are Non-degenerate forms.

The remaining 8 of the total 16 are all non-degenerate forms which are discussed below one by one.

Related Articles:

AND-OR

In AND-OR combination the first level gate is AND gate and the second level gate is OR gate. This combination implements Sum of Product (SOP) form as shown in the figure below;

A . B + C . D

AND-OR Combination

NAND-NAND

NAND is a universal gate and its NAND-NAND combination is used for implementing Sum of Product form just like AND-OR combination. The conversion of NAND-NAND from AND-OR has been briefly discussed in NAND implementation.

(( A . B )’ ( C . D )’)’               =             ( A . B ) + ( C . D )

NAND-NAND Combination

OR-AND

In OR-AND combination first level gate is OR gate and the Second level gate is AND gate. OR-AND combination is used for implementing the Product of Sum form.

Its schematic is given in the figure below.

( A + B )  ( C + D )

OR-AND Combination

NOR-NOR

NOR is also a universal gate and its NOR-NOR combination can be used instead of OR-AND combination because it also implements Product of Sum form.

Its schematic is given below.

 (( A + B )’ + ( C + D )’)’               =             ( A + B )  ( C + D )

NOR-NOR combination

AND-NOR

AND-NOR combination is used for implementing a compound logic known as AND-OR-INVERT (AOI). AND-NOR combination resembles AND-OR combination but there is inversion at the output of NOT gate which implements the INVERT part of AND-OR-INVERT.

The expression of AOI function is given below.

F    =      ( AB + C D + E )’

Its schematic is given below.

AND-NOR CombinationRelated Post:

NAND-AND

NAND-AND can also be used to implement AND-OR-INVERT (AOI) form. Its expression can be converted into AOI as given below

(  AB  )’  (  CD  )’           =             (  AB  +  CD )’

Schematic of AND-NOR can be converted into NAND-AND as shown in the example below.

AND-OR form of AND-OR-INVERT

Figure (a) is the AND-OR form of AND-OR-INVERT.

NOR Gate and INVERT-AND Gate

In figure (b) we replace NOR gate with its equivalent INVERT-AND gate. NOR and INVERT-AND are the same gates with different graphical symbols.

Two-Level Logic Implementation NAND gate

 In figure (c) the bubble of the input of 2nd level AND gate will move to the output of first level AND gate thus making it NAND gate. The single input will be complemented or an inverter will be inserted to compensate the bubble

OR-NAND

OR-NAND form is used to implement a compound logic OR-AND-INVERT (OAI). OR-NAND resembles OR-AND but there is inversion at the output of NAND gate which is why it can implement OAI logic.

OAI logic function is given below.

[( A+B )  ( C + D ) E]’

Its schematic is given below.

schematic of OR-NAND

NOR-OR

This combination is used for implementing OAI same as OR-NAND combination.

Its expression is given below.

( A + B )’ + ( C + D )’         =         [( A + B ) ( C+D )]’

The OR-NAND form can be graphically converted into NOR-OR as shown in the figure given below.

schematic of OR-NAND

In figure (a), the given schematic is in OR-NAND form.

NAND gate replaced with equivalent INVERT-OR gate

In figure (b), NAND gate has been replaced with its equivalent INVERT-OR gate.

Two-Level Logic Implementation NOR gate

In figure (c), the bubbles at the input of 2nd level OR gate is moved to the output of 1st level OR gate. This bubble makes it NOR gate. The single input will be either complemented or an inverter will be inserted to compensate the last bubble. In this case, I have added an inverter in the path of the last bubble.

➡️ READ FULL ARTICLE 📖

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button